Experimental cyclic performance of cold-formed steel bolted moment resisting frames. (15th February 2019)
- Record Type:
- Journal Article
- Title:
- Experimental cyclic performance of cold-formed steel bolted moment resisting frames. (15th February 2019)
- Main Title:
- Experimental cyclic performance of cold-formed steel bolted moment resisting frames
- Authors:
- McCrum, Daniel P.
Simon, Jordan
Grimes, Michael
Broderick, Brian M.
Lim, James B.P.
Wrzesien, Andrzej M. - Abstract:
- Highlights: Cyclic testing of cold-formed steel portal frames. Perfect-fit and normal tolerance bolt hole connection types investigated. Good seismic performance through ductility and energy dissipation capacity. Normal tolerance bolt hole connection has greater ductility and energy dissipation capacity. Bi-moment should be considered by designers as it is the second largest stress after major axis bending. Abstract: This paper investigates the seismic performance of a single storey moment resisting cold-formed steel (CFS) portal frame through cyclic testing. Six monotonic and six cyclic tests were performed on three different section sizes of CFS. The portal frames were 3.2 m long × 2.2 m high and the CFS sections bolted with either perfect-fit tolerance bolt holes (PTBH) or normal tolerance bolt holes (NTBH) connections. Connections with NTBH are standard in CFS, but connections with PTBH are often only used for short-spanning frames. Results from the tests demonstrated that both PTBH and NTBH connections had stable hysteresis and good hysteretic energy dissipation capacity and ductility. On average, the NTBH connections performed better under cyclic loading in comparison to the PTBH connections (5.4% larger ductility and 22.3% increased energy dissipation). Strain gauge results show failure due to combined bending and bi-moment stresses, of which the bi-moment stress component accounted for 41% of the total longitudinal stresses at the section web. It should be noted thatHighlights: Cyclic testing of cold-formed steel portal frames. Perfect-fit and normal tolerance bolt hole connection types investigated. Good seismic performance through ductility and energy dissipation capacity. Normal tolerance bolt hole connection has greater ductility and energy dissipation capacity. Bi-moment should be considered by designers as it is the second largest stress after major axis bending. Abstract: This paper investigates the seismic performance of a single storey moment resisting cold-formed steel (CFS) portal frame through cyclic testing. Six monotonic and six cyclic tests were performed on three different section sizes of CFS. The portal frames were 3.2 m long × 2.2 m high and the CFS sections bolted with either perfect-fit tolerance bolt holes (PTBH) or normal tolerance bolt holes (NTBH) connections. Connections with NTBH are standard in CFS, but connections with PTBH are often only used for short-spanning frames. Results from the tests demonstrated that both PTBH and NTBH connections had stable hysteresis and good hysteretic energy dissipation capacity and ductility. On average, the NTBH connections performed better under cyclic loading in comparison to the PTBH connections (5.4% larger ductility and 22.3% increased energy dissipation). Strain gauge results show failure due to combined bending and bi-moment stresses, of which the bi-moment stress component accounted for 41% of the total longitudinal stresses at the section web. It should be noted that bi-moment stresses are often incorrectly ignored by practitioners; the experimental test results thus show that by doing so the sections would fail at 59% of the design moment. Initial failure was localised at the top of the column sections in the form of local buckling at the web-to-flange junction under compressive stresses. Several load cycles past the initial buckling stage led to a further reduction of steel ductility due to strain hardening and strain ageing leading to fracture of the steel in the section corners. The buckling/tearing failure in the columns would result in a reduced axial load carrying capacity. … (more)
- Is Part Of:
- Engineering structures. Volume 181(2019)
- Journal:
- Engineering structures
- Issue:
- Volume 181(2019)
- Issue Display:
- Volume 181, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 181
- Issue:
- 2019
- Issue Sort Value:
- 2019-0181-2019-0000
- Page Start:
- 1
- Page End:
- 14
- Publication Date:
- 2019-02-15
- Subjects:
- Cold-formed steel portal frames -- Cyclic testing -- Moment resisting frame -- Connections with perfect-fit tolerance bolt holes -- Connection with normal tolerance bolt holes
Structural engineering -- Periodicals
Structural analysis (Engineering) -- Periodicals
Construction, Technique de la -- Périodiques
Génie parasismique -- Périodiques
Pression du vent -- Périodiques
Earthquake engineering
Structural engineering
Wind-pressure
Periodicals
624.105 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01410296 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.engstruct.2018.11.063 ↗
- Languages:
- English
- ISSNs:
- 0141-0296
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3770.032000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11580.xml