SHORE‐based detection and imputation of dropout in diffusion MRI. Issue 6 (4th July 2019)
- Record Type:
- Journal Article
- Title:
- SHORE‐based detection and imputation of dropout in diffusion MRI. Issue 6 (4th July 2019)
- Main Title:
- SHORE‐based detection and imputation of dropout in diffusion MRI
- Authors:
- Koch, Alexandra
Zhukov, Andrei
Stöcker, Tony
Groeschel, Samuel
Schultz, Thomas - Abstract:
- Abstract : Purpose: In diffusion MRI, dropout refers to a strong attenuation of the measured signal that is caused by bulk motion during the diffusion encoding. When left uncorrected, dropout will be erroneously interpreted as high diffusivity in the affected direction. We present a method to automatically detect dropout, and to replace the affected measurements with imputed values. Methods: Signal dropout is detected by deriving an outlier score from a simple harmonic oscillator‐based reconstruction and estimation (SHORE) fit of all measurements. The outlier score is defined to detect measurements that are substantially lower than predicted by SHORE in a relative sense, while being less sensitive to measurement noise in cases of weak baseline signal. A second SHORE fit is based on detected inliers only, and its predictions are used to replace outliers. Results: Our method is shown to reliably detect and accurately impute dropout in simulated data, and to achieve plausible results in corrupted in vivo dMRI measurements. Computational effort is much lower than with previously proposed alternatives. Conclusions: Deriving a suitable outlier score from SHORE results in a fast and accurate method for detection and imputation of dropout in diffusion MRI. It requires measurements with multiple b values (such as multi‐shell or DSI), but is independent from the models used for analysis (such as DKI, NODDI, deconvolution, etc.).
- Is Part Of:
- Magnetic resonance in medicine. Volume 82:Issue 6(2019)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 82:Issue 6(2019)
- Issue Display:
- Volume 82, Issue 6 (2019)
- Year:
- 2019
- Volume:
- 82
- Issue:
- 6
- Issue Sort Value:
- 2019-0082-0006-0000
- Page Start:
- 2286
- Page End:
- 2298
- Publication Date:
- 2019-07-04
- Subjects:
- diffusion MRI -- diffusion spectrum imaging -- dropout -- multi‐shell -- outliers -- SHORE
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.27893 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11536.xml