Comparison of time and frequency domain features' immunity against lift-off in pulse-compression eddy current imaging. (October 2019)
- Record Type:
- Journal Article
- Title:
- Comparison of time and frequency domain features' immunity against lift-off in pulse-compression eddy current imaging. (October 2019)
- Main Title:
- Comparison of time and frequency domain features' immunity against lift-off in pulse-compression eddy current imaging
- Authors:
- Ferrigno, Luigi
Laracca, Marco
Malekmohammadi, Hamed
Tian, Gui Yun
Ricci, Marco - Abstract:
- Abstract: This paper reports a comparison between imaging procedures based on time- and frequency-domain features applied to eddy current data collected on an Aluminium alloy benchmark sample. Both the defect detection capability and the immunity against lift-off are analysed. Historically, the pulsed eddy current method was introduced to improve the performance of eddy current testing both in terms of increased penetration depth and lift-off invariance by exploiting time-domain features analysis, commonly precluded when using single- or multi-tone excitations. In this work, such analysis is instead accomplished by using a swept-frequency excitation signal along with an optimized pulse-compression procedure. This approach allows the user to easily tune the energy delivered to the system by increasing the sweep duration to improve on demand the resultant Signal-to-Noise Ratio (SNR) without losing the capability of time-domain feature extraction. The imaging procedure makes use of amplitude and phase features of both frequency- and time-domain data where time-phase is defined through the Hilbert transform of the pulse-compression output. The detection capability of various imaging strategies, namely A-, B- and C-scans, are compared in terms of inspection depth and lift-off robustness by using the SNR merit factor. It is shown that time-domain features outperform frequency-based ones in terms of SNR for the case of deeper defects and that phase features are robust againstAbstract: This paper reports a comparison between imaging procedures based on time- and frequency-domain features applied to eddy current data collected on an Aluminium alloy benchmark sample. Both the defect detection capability and the immunity against lift-off are analysed. Historically, the pulsed eddy current method was introduced to improve the performance of eddy current testing both in terms of increased penetration depth and lift-off invariance by exploiting time-domain features analysis, commonly precluded when using single- or multi-tone excitations. In this work, such analysis is instead accomplished by using a swept-frequency excitation signal along with an optimized pulse-compression procedure. This approach allows the user to easily tune the energy delivered to the system by increasing the sweep duration to improve on demand the resultant Signal-to-Noise Ratio (SNR) without losing the capability of time-domain feature extraction. The imaging procedure makes use of amplitude and phase features of both frequency- and time-domain data where time-phase is defined through the Hilbert transform of the pulse-compression output. The detection capability of various imaging strategies, namely A-, B- and C-scans, are compared in terms of inspection depth and lift-off robustness by using the SNR merit factor. It is shown that time-domain features outperform frequency-based ones in terms of SNR for the case of deeper defects and that phase features are robust against lift-off variations for both time and frequency domains. In addition, the analysis of time-amplitude images clearly shows the presence of lift-off invariant points. To our knowledge, this is the first experimental evidence of the lift-off invariance points retrieved after applying pulse-compression in combination with coded excitation instead of using directly pulsed, multi-tone or single-tone sinusoidal signals. This not only confirms previous results achieved by the authors but also demonstrates that pulse-compression eddy current can represent a solution to combine the advantages of pulsed and sinusoidal excitation strategies. … (more)
- Is Part Of:
- NDT & E international. Volume 107(2019)
- Journal:
- NDT & E international
- Issue:
- Volume 107(2019)
- Issue Display:
- Volume 107, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 107
- Issue:
- 2019
- Issue Sort Value:
- 2019-0107-2019-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-10
- Subjects:
- Eddy current testing -- Eddy current imaging -- Lift-off invariance (LOI) -- Pulse-compression
Nondestructive testing -- Periodicals
Contrôle non destructif -- Périodiques
Electronic journals
620.1127 - Journal URLs:
- http://www.sciencedirect.com/science/journal/09638695 ↗
http://www.elsevier.com/journals ↗
http://www.elsevier.com/homepage/elecserv.htt ↗ - DOI:
- 10.1016/j.ndteint.2019.102152 ↗
- Languages:
- English
- ISSNs:
- 0963-8695
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6067.859000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11536.xml