Correction of phase errors in quantitative water–fat imaging using a monopolar time‐interleaved multi‐echo gradient echo sequence. Issue 3 (31st October 2016)
- Record Type:
- Journal Article
- Title:
- Correction of phase errors in quantitative water–fat imaging using a monopolar time‐interleaved multi‐echo gradient echo sequence. Issue 3 (31st October 2016)
- Main Title:
- Correction of phase errors in quantitative water–fat imaging using a monopolar time‐interleaved multi‐echo gradient echo sequence
- Authors:
- Ruschke, Stefan
Eggers, Holger
Kooijman, Hendrik
Diefenbach, Maximilian N.
Baum, Thomas
Haase, Axel
Rummeny, Ernst J.
Hu, Houchun H.
Karampinos, Dimitrios C. - Abstract:
- Abstract : Purpose: To propose a phase error correction scheme for monopolar time‐interleaved multi‐echo gradient echo water–fat imaging that allows accurate and robust complex‐based quantification of the proton density fat fraction (PDFF). Methods: A three‐step phase correction scheme is proposed to address a) a phase term induced by echo misalignments that can be measured with a reference scan using reversed readout polarity, b) a phase term induced by the concomitant gradient field that can be predicted from the gradient waveforms, and c) a phase offset between time‐interleaved echo trains. Simulations were carried out to characterize the concomitant gradient field‐induced PDFF bias and the performance estimating the phase offset between time‐interleaved echo trains. Phantom experiments and in vivo liver and thigh imaging were performed to study the relevance of each of the three phase correction steps on PDFF accuracy and robustness. Results: The simulation, phantom, and in vivo results showed in agreement with the theory an echo time‐dependent PDFF bias introduced by the three phase error sources. The proposed phase correction scheme was found to provide accurate PDFF estimation independent of the employed echo time combination. Conclusion: Complex‐based time‐interleaved water–fat imaging was found to give accurate and robust PDFF measurements after applying the proposed phase error correction scheme. Magn Reson Med 78:984–996, 2017. © 2016 International Society forAbstract : Purpose: To propose a phase error correction scheme for monopolar time‐interleaved multi‐echo gradient echo water–fat imaging that allows accurate and robust complex‐based quantification of the proton density fat fraction (PDFF). Methods: A three‐step phase correction scheme is proposed to address a) a phase term induced by echo misalignments that can be measured with a reference scan using reversed readout polarity, b) a phase term induced by the concomitant gradient field that can be predicted from the gradient waveforms, and c) a phase offset between time‐interleaved echo trains. Simulations were carried out to characterize the concomitant gradient field‐induced PDFF bias and the performance estimating the phase offset between time‐interleaved echo trains. Phantom experiments and in vivo liver and thigh imaging were performed to study the relevance of each of the three phase correction steps on PDFF accuracy and robustness. Results: The simulation, phantom, and in vivo results showed in agreement with the theory an echo time‐dependent PDFF bias introduced by the three phase error sources. The proposed phase correction scheme was found to provide accurate PDFF estimation independent of the employed echo time combination. Conclusion: Complex‐based time‐interleaved water–fat imaging was found to give accurate and robust PDFF measurements after applying the proposed phase error correction scheme. Magn Reson Med 78:984–996, 2017. © 2016 International Society for Magnetic Resonance in Medicine. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 78:Issue 3(2017)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 78:Issue 3(2017)
- Issue Display:
- Volume 78, Issue 3 (2017)
- Year:
- 2017
- Volume:
- 78
- Issue:
- 3
- Issue Sort Value:
- 2017-0078-0003-0000
- Page Start:
- 984
- Page End:
- 996
- Publication Date:
- 2016-10-31
- Subjects:
- chemical shift encoding‐based water–fat separation -- fat quantification -- proton density fat fraction (PDFF) -- complex‐based water–fat separation -- echo misalignments -- concomitant gradient field -- phase correction
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.26485 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11515.xml