Susceptibility underestimation in a high‐susceptibility phantom: Dependence on imaging resolution, magnitude contrast, and other parameters. Issue 3 (3rd October 2016)
- Record Type:
- Journal Article
- Title:
- Susceptibility underestimation in a high‐susceptibility phantom: Dependence on imaging resolution, magnitude contrast, and other parameters. Issue 3 (3rd October 2016)
- Main Title:
- Susceptibility underestimation in a high‐susceptibility phantom: Dependence on imaging resolution, magnitude contrast, and other parameters
- Authors:
- Zhou, Dong
Cho, Junghun
Zhang, Jingwei
Spincemaille, Pascal
Wang, Yi - Abstract:
- Abstract : Purpose: We assessed the accuracy of quantitative susceptibility mapping in a gadolinium balloon phantom with a large range of susceptibility values and imaging resolutions at 1.5 and 3 Tesla (T). Theory and Methods: The phantom contained sources with susceptibility values of 0.4, 0.8, 1.6, and 3.2 ppm and was imaged at isotropic resolutions of 0.7, 0.8, 1.2, and 1.8 mm. Numerical simulations were performed to match the experimental findings. Voxel sensitivity effects were used to explain the susceptibility underestimations. Results: Both phantom data and simulation demonstrated that systematic underestimation of the susceptibility values increased with voxel size, field strength, and object susceptibility. Conclusion: The underestimation originates from the signal formation in a voxel, which can be described by the voxel sensitivity function. The amount of underestimation is thus affected by imaging resolution, magnitude contrast, image filtering, and details of the susceptibility inclusions such as the susceptibility value and geometry. High‐resolution imaging is therefore needed for accurate reconstruction of QSM values, especially at higher susceptibilities. Magn Reson Med 78:1080–1086, 2017. © 2016 International Society for Magnetic Resonance in Medicine
- Is Part Of:
- Magnetic resonance in medicine. Volume 78:Issue 3(2017)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 78:Issue 3(2017)
- Issue Display:
- Volume 78, Issue 3 (2017)
- Year:
- 2017
- Volume:
- 78
- Issue:
- 3
- Issue Sort Value:
- 2017-0078-0003-0000
- Page Start:
- 1080
- Page End:
- 1086
- Publication Date:
- 2016-10-03
- Subjects:
- magnetic susceptibility -- underestimation -- imaging resolution -- sample orientation -- voxel sensitivity function -- k‐space filter
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.26475 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11515.xml