Diagnostic accuracy of intracellular uptake rates calculated using dynamic Gd‐EOB‐DTPA‐enhanced MRI for hepatic fibrosis stage. Issue 4 (16th August 2016)
- Record Type:
- Journal Article
- Title:
- Diagnostic accuracy of intracellular uptake rates calculated using dynamic Gd‐EOB‐DTPA‐enhanced MRI for hepatic fibrosis stage. Issue 4 (16th August 2016)
- Main Title:
- Diagnostic accuracy of intracellular uptake rates calculated using dynamic Gd‐EOB‐DTPA‐enhanced MRI for hepatic fibrosis stage
- Authors:
- Juluru, Krishna
Talal, Andrew H.
Yantiss, Rhonda K.
Spincemaille, Pascal
Weidman, Elizabeth K.
Giambrone, Ashley E.
Jalili, Sadaf
Sourbron, Steven P.
Dyke, Jonathan P. - Abstract:
- Abstract : Purpose: To assess the diagnostic accuracy of intracellular uptake rates ( K i ), and other quantitative pharmacokinetic (PK) parameters, for hepatic fibrosis stage; to compare this accuracy with a previously published semiquantitative metric, contrast enhancement index (CEI); and to assess variability of these parameters between liver regions. Materials and Methods: This was a case–control study design. Dynamic Gd‐EOB‐DTPA‐enhanced 1.5T magnetic resonance imaging (MRI) was performed prospectively in 22 subjects with varying known stages of hepatic fibrosis. PK parameters and CEI were derived from the whole livers and from three fixed regions of interest (ROIs) in all subjects. Spearman rank correlation coefficients were computed to assess the relationship between fibrosis stages and each parameter. Receiver operating characteristic (ROC) curves were constructed to discriminate severe fibrosis (stages 3–4) from nonsevere fibrosis (stages 0–2). The coefficient of variation (CV) was calculated to assess variability in parameters between ROIs. Results: K i and fibrosis stage were significantly correlated (R = –0.55, 95% confidence interval [CI] [–0.79, –0.14], P = 0.01). Area under ROC curve (AUC) in distinguishing severe from nonsevere fibrosis for K i was 0.84 (95% CI [0.65, 1.00]), and for CEI was 0.64 (95% CI [0.39, 0.89]) ( P = 0.0248). CV for K i and CEI were 33.4 and 5.8, respectively. The only other parameter in the PK model having significant correlationAbstract : Purpose: To assess the diagnostic accuracy of intracellular uptake rates ( K i ), and other quantitative pharmacokinetic (PK) parameters, for hepatic fibrosis stage; to compare this accuracy with a previously published semiquantitative metric, contrast enhancement index (CEI); and to assess variability of these parameters between liver regions. Materials and Methods: This was a case–control study design. Dynamic Gd‐EOB‐DTPA‐enhanced 1.5T magnetic resonance imaging (MRI) was performed prospectively in 22 subjects with varying known stages of hepatic fibrosis. PK parameters and CEI were derived from the whole livers and from three fixed regions of interest (ROIs) in all subjects. Spearman rank correlation coefficients were computed to assess the relationship between fibrosis stages and each parameter. Receiver operating characteristic (ROC) curves were constructed to discriminate severe fibrosis (stages 3–4) from nonsevere fibrosis (stages 0–2). The coefficient of variation (CV) was calculated to assess variability in parameters between ROIs. Results: K i and fibrosis stage were significantly correlated (R = –0.55, 95% confidence interval [CI] [–0.79, –0.14], P = 0.01). Area under ROC curve (AUC) in distinguishing severe from nonsevere fibrosis for K i was 0.84 (95% CI [0.65, 1.00]), and for CEI was 0.64 (95% CI [0.39, 0.89]) ( P = 0.0248). CV for K i and CEI were 33.4 and 5.8, respectively. The only other parameter in the PK model having significant correlation with fibrosis stage was absolute arterial blood flow ( F a ) (R = –0.48, 95% CI [−0.75, −0.05], P = 0.03). Conclusion: Hepatocyte intracellular uptake rate, Ki, derived from dynamic contrast‐enhanced MRI, correlates with fibrosis stage and may contribute to a noninvasive biomarker of hepatic fibrosis. Level of Evidence: 2 J. Magn. Reson. Imaging 2017;45:1177–1185 … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 45:Issue 4(2017)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 45:Issue 4(2017)
- Issue Display:
- Volume 45, Issue 4 (2017)
- Year:
- 2017
- Volume:
- 45
- Issue:
- 4
- Issue Sort Value:
- 2017-0045-0004-0000
- Page Start:
- 1177
- Page End:
- 1185
- Publication Date:
- 2016-08-16
- Subjects:
- dynamic contrast enhanced MRI -- DCE‐MRI -- perfusion -- input -- compartment -- hepatic fibrosis -- liver -- Gd‐EOB‐DTPA
Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.25431 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11490.xml