Accelerated phase contrast MRI using hybrid one‐ and two‐sided flow encodings only (HOTFEO). (8th March 2018)
- Record Type:
- Journal Article
- Title:
- Accelerated phase contrast MRI using hybrid one‐ and two‐sided flow encodings only (HOTFEO). (8th March 2018)
- Main Title:
- Accelerated phase contrast MRI using hybrid one‐ and two‐sided flow encodings only (HOTFEO)
- Authors:
- Wang, Da
Chien, Aichi
Shao, Jiaxin
Ali, Fadil Abbas
Hu, Peng - Abstract:
- Abstract : The aim of this work was to develop and evaluate a fast phase contrast magnetic resonance imaging (PC‐MRI) technique with hybrid one‐ and two‐sided flow encodings only (HOTFEO) for accurate blood flow and velocity measurements of three‐directional velocity encoding PC‐MRI. Four‐dimensional (4D) PC‐MRI acquires flow‐compensated (FC) and three‐directional flow‐encoded (FE) echoes in an interleaved fashion. We hypothesize that the blood flow velocity direction (not magnitude) has minimal change between two consecutive cardiac phases. This assumption provides a velocity direction constraint that can achieve 4/3‐fold acceleration using three‐directional FE data to calculate FC data instead of acquiring them. The HOTFEO acquisition pattern can address the ill‐conditioned constraint and improve the calculation accuracy. HOTFEO was evaluated in healthy volunteers and compared with conventional two‐dimensional (2D) and 4D flow imaging techniques with FC and three‐directional FE acquisitions (FC/3FE). Compared with FC/3FE, Bland–Altman tests showed that the 4/3‐fold accelerated HOTFEO technique resulted in relatively small bias error for total volumetric flow (0.89% for prospective 2D data, –1.19% for retrospective 4D data and –3.40% for prospective 4D data) and maximum peak velocity (0.50% for prospective 2D data, –0.17% for retrospective 4D data and –2.00% for prospective 4D data) measurements in common carotid arteries. HOTFEO can accelerate three‐directional velocityAbstract : The aim of this work was to develop and evaluate a fast phase contrast magnetic resonance imaging (PC‐MRI) technique with hybrid one‐ and two‐sided flow encodings only (HOTFEO) for accurate blood flow and velocity measurements of three‐directional velocity encoding PC‐MRI. Four‐dimensional (4D) PC‐MRI acquires flow‐compensated (FC) and three‐directional flow‐encoded (FE) echoes in an interleaved fashion. We hypothesize that the blood flow velocity direction (not magnitude) has minimal change between two consecutive cardiac phases. This assumption provides a velocity direction constraint that can achieve 4/3‐fold acceleration using three‐directional FE data to calculate FC data instead of acquiring them. The HOTFEO acquisition pattern can address the ill‐conditioned constraint and improve the calculation accuracy. HOTFEO was evaluated in healthy volunteers and compared with conventional two‐dimensional (2D) and 4D flow imaging techniques with FC and three‐directional FE acquisitions (FC/3FE). Compared with FC/3FE, Bland–Altman tests showed that the 4/3‐fold accelerated HOTFEO technique resulted in relatively small bias error for total volumetric flow (0.89% for prospective 2D data, –1.19% for retrospective 4D data and –3.40% for prospective 4D data) and maximum peak velocity (0.50% for prospective 2D data, –0.17% for retrospective 4D data and –2.00% for prospective 4D data) measurements in common carotid arteries. HOTFEO can accelerate three‐directional velocity encoding PC‐MRI whilst maintaining the measurement accuracy of the total volumetric flow and maximum peak velocity. Abstract : We hypothesize that the blood flow velocity direction (not magnitude) shows minimum change between two consecutive cardiac phases. This assumption provides a velocity direction constraint that can achieve 4/3‐fold acceleration using three‐directional flow encoding data to calculate flow compensation data instead of acquiring them. Hybrid one‐ and two‐sided flow encodings only (HOTFEO) can accelerate three‐directional velocity encoding phase contrast magnetic resonance imaging (PC‐MRI) whilst maintaining the measurement accuracy of the total volumetric flow and maximum total peak velocity. … (more)
- Is Part Of:
- NMR in biomedicine. Volume 31:Number 5(2018)
- Journal:
- NMR in biomedicine
- Issue:
- Volume 31:Number 5(2018)
- Issue Display:
- Volume 31, Issue 5 (2018)
- Year:
- 2018
- Volume:
- 31
- Issue:
- 5
- Issue Sort Value:
- 2018-0031-0005-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2018-03-08
- Subjects:
- 4D flow -- fast phase contrast MRI -- flow quantification -- hybrid one‐ and two‐sided flow encoding only -- temporal resolution and temporal footprint -- velocity direction constraint
Nuclear magnetic resonance -- Periodicals
Magnetic Resonance Spectroscopy -- Periodicals
574 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/nbm.3904 ↗
- Languages:
- English
- ISSNs:
- 0952-3480
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6113.931000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11490.xml