Combining Radon transform and electrical capacitance tomography for a 2d + 1 imaging device. (1st August 2018)
- Record Type:
- Journal Article
- Title:
- Combining Radon transform and electrical capacitance tomography for a 2d + 1 imaging device. (1st August 2018)
- Main Title:
- Combining Radon transform and electrical capacitance tomography for a 2d + 1 imaging device
- Authors:
- Capdeboscq, Yves
Mamigonians, Hrand
Sulaimalebbe, Aslam
Tshitoyan, Vahe - Abstract:
- Abstract: This paper describes a coplanar non invasive non destructive capacitive imaging device. We first introduce a mathematical model for its output, and discuss some of its theoretical capabilities. We show that the data obtained from this device can be interpreted as a weighted Radon transform of the electrical permittivity of the measured object near its surface. Image reconstructions from experimental data provide good surface resolution as well as short depth imaging, making the apparatus a 2 d + 1 imager. The quality of the images leads us to expect that excellent results can be delivered by ad hoc optimized inversion formulas. There are also interesting, yet unexplored, theoretical questions on imaging that this sensor will allow us to test.
- Is Part Of:
- Inverse problems. Volume 34:Number 10(2018:Oct.)
- Journal:
- Inverse problems
- Issue:
- Volume 34:Number 10(2018:Oct.)
- Issue Display:
- Volume 34, Issue 10 (2018)
- Year:
- 2018
- Volume:
- 34
- Issue:
- 10
- Issue Sort Value:
- 2018-0034-0010-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-08-01
- Subjects:
- radon transform -- electrical capacitance tomography -- instrumentation and measurements -- non invasive detection -- coplanar capacitive imaging device
Inverse problems (Differential equations) -- Periodicals
515.357 - Journal URLs:
- http://iopscience.iop.org/0266-5611 ↗
http://ioppublishing.org/ ↗ - DOI:
- 10.1088/1361-6420/aad344 ↗
- Languages:
- English
- ISSNs:
- 0266-5611
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11503.xml