Spectral correction for handheld optoacoustic imaging by means of near‐infrared optical tomography in reflection mode. Issue 1 (2nd October 2018)
- Record Type:
- Journal Article
- Title:
- Spectral correction for handheld optoacoustic imaging by means of near‐infrared optical tomography in reflection mode. Issue 1 (2nd October 2018)
- Main Title:
- Spectral correction for handheld optoacoustic imaging by means of near‐infrared optical tomography in reflection mode
- Authors:
- Ulrich, Leonie
Ahnen, Linda
Akarçay, Hidayet Günhan
Majos, Salvador Sánchez
Jaeger, Michael
Held, Kai Gerrit
Wolf, Martin
Frenz, Martin - Abstract:
- Abstract : In vivo imaging of tissue/vasculature oxygen saturation levels is of prime interest in many clinical applications. To this end, the feasibility of combining two distinct and complementary imaging modalities is investigated: optoacoustics (OA) and near‐infrared optical tomography (NIROT), both operating noninvasively in reflection mode. Experiments were conducted on two optically heterogeneous phantoms mimicking tissue before and after the occurrence of a perturbation. OA imaging was used to resolve submillimetric vessel‐like optical absorbers at depths up to 25 mm, but with a spectral distortion in the OA signals. NIROT measurements were utilized to image perturbations in the background and to estimate the light fluence inside the phantoms at the wavelength pair (760 nm, 830 nm). This enabled the spectral correction of the vessel‐like absorbers' OA signals: the error in the ratio of the absorption coefficient at 830 nm to that at 760 nm was reduced from 60%‐150% to 10%‐20%. The results suggest that oxygen saturation ( SO 2 ) levels in arteries can be determined with <10% error and furthermore, that relative changes in vessels' SO 2 can be monitored with even better accuracy. The outcome relies on a proper identification of the OA signals emanating from the studied vessels. Abstract : Optoacoustics (OA) is combined with near‐infrared optical tomography (NIROT) in reflection mode to quantitatively image vasculature oxygen saturation ( SO 2 ) levels in phantomsAbstract : In vivo imaging of tissue/vasculature oxygen saturation levels is of prime interest in many clinical applications. To this end, the feasibility of combining two distinct and complementary imaging modalities is investigated: optoacoustics (OA) and near‐infrared optical tomography (NIROT), both operating noninvasively in reflection mode. Experiments were conducted on two optically heterogeneous phantoms mimicking tissue before and after the occurrence of a perturbation. OA imaging was used to resolve submillimetric vessel‐like optical absorbers at depths up to 25 mm, but with a spectral distortion in the OA signals. NIROT measurements were utilized to image perturbations in the background and to estimate the light fluence inside the phantoms at the wavelength pair (760 nm, 830 nm). This enabled the spectral correction of the vessel‐like absorbers' OA signals: the error in the ratio of the absorption coefficient at 830 nm to that at 760 nm was reduced from 60%‐150% to 10%‐20%. The results suggest that oxygen saturation ( SO 2 ) levels in arteries can be determined with <10% error and furthermore, that relative changes in vessels' SO 2 can be monitored with even better accuracy. The outcome relies on a proper identification of the OA signals emanating from the studied vessels. Abstract : Optoacoustics (OA) is combined with near‐infrared optical tomography (NIROT) in reflection mode to quantitatively image vasculature oxygen saturation ( SO 2 ) levels in phantoms containing vessels at depths up to 25 mm. Using NIROT to estimate the light fluence, the OA signals' spectral distortion was reduced from 60%‐150% to 10%‐20%. Results suggest that SO 2 levels can be determined with <10% error and that temporal changes can be monitored with even better accuracy. … (more)
- Is Part Of:
- Journal of biophotonics. Volume 12:Issue 1(2019)
- Journal:
- Journal of biophotonics
- Issue:
- Volume 12:Issue 1(2019)
- Issue Display:
- Volume 12, Issue 1 (2019)
- Year:
- 2019
- Volume:
- 12
- Issue:
- 1
- Issue Sort Value:
- 2019-0012-0001-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2018-10-02
- Subjects:
- blood oxygen saturation -- fluence compensation -- multimodal imaging -- near‐infrared optical tomography -- optoacoustic signal quantification -- quantitative optoacoustic imaging -- spectral correction
Photonics -- Periodicals
Optical materials -- Periodicals
Optics -- Periodicals
Medical instruments and apparatus -- Periodicals
621.3605 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1864-0648 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jbio.201800112 ↗
- Languages:
- English
- ISSNs:
- 1864-063X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11485.xml