Feasibility of ultra-low radiation dose digital subtraction angiography: Preliminary study in a simplified cerebral angiography phantom. Issue 5 (October 2019)
- Record Type:
- Journal Article
- Title:
- Feasibility of ultra-low radiation dose digital subtraction angiography: Preliminary study in a simplified cerebral angiography phantom. Issue 5 (October 2019)
- Main Title:
- Feasibility of ultra-low radiation dose digital subtraction angiography: Preliminary study in a simplified cerebral angiography phantom
- Authors:
- Maeng, Jun Young
Song, Yunsun
Sung, Yu Sub
Kim, Tae-Il
Lee, Deok Hee
Kim, Tae-Hyung - Abstract:
- Introduction: The objective of this article is to evaluate the feasibility of cerebral digital subtraction angiography (DSA) using ultra-low radiation dose settings in a simplified cerebral angiography phantom. Materials and methods: We created a silicone phantom capable of producing a simplified cerebral DSA. A total of 18 DSA sets were obtained with gradual six-step reduction of the detector entrance dose (DED) from 1.82 to 0.08 μGy per frame, while standard, postprocessing algorithm (PPA) and copper filter (0.3 mm) with PPA (CwP) algorithm reconstruction protocols were applied. We quantitatively compared their signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) and qualitatively analyzed the images' qualities in terms of image sharpness, contrast, and noise as investigated by five observers. Results: The SNR and CNR, which decreased with lowering of the DED in the standard protocol group, were significantly compensated by using the PPA. The values were approximately double in the PPA (11.5 ± 2.9) and CwP (11.0 ± 2.5) groups compared with the standard (5.4 ± 1.1) group in the DED of 0.24 μGy per frame as well as in the other values. The total scores of the observers according to the protocols showed a tendency to decrease as the DED lowered. On average, the PPA (96.3 ± 34.6) and CwP (91.3 ± 29.9) groups yielded higher results than the standard protocol (83.7 ± 46.7). Conclusion: Given that the current DED ranges from 1.82 to 3.60 μGy per frame for routineIntroduction: The objective of this article is to evaluate the feasibility of cerebral digital subtraction angiography (DSA) using ultra-low radiation dose settings in a simplified cerebral angiography phantom. Materials and methods: We created a silicone phantom capable of producing a simplified cerebral DSA. A total of 18 DSA sets were obtained with gradual six-step reduction of the detector entrance dose (DED) from 1.82 to 0.08 μGy per frame, while standard, postprocessing algorithm (PPA) and copper filter (0.3 mm) with PPA (CwP) algorithm reconstruction protocols were applied. We quantitatively compared their signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) and qualitatively analyzed the images' qualities in terms of image sharpness, contrast, and noise as investigated by five observers. Results: The SNR and CNR, which decreased with lowering of the DED in the standard protocol group, were significantly compensated by using the PPA. The values were approximately double in the PPA (11.5 ± 2.9) and CwP (11.0 ± 2.5) groups compared with the standard (5.4 ± 1.1) group in the DED of 0.24 μGy per frame as well as in the other values. The total scores of the observers according to the protocols showed a tendency to decrease as the DED lowered. On average, the PPA (96.3 ± 34.6) and CwP (91.3 ± 29.9) groups yielded higher results than the standard protocol (83.7 ± 46.7). Conclusion: Given that the current DED ranges from 1.82 to 3.60 μGy per frame for routine cerebral DSA, our results indicate that DED can be decreased to 15%–30% of the current dose level in vessels 2–4 mm in diameter if image-improvement algorithms are applied. … (more)
- Is Part Of:
- Interventional neuroradiology. Volume 25:Issue 5(2019:Oct.)
- Journal:
- Interventional neuroradiology
- Issue:
- Volume 25:Issue 5(2019:Oct.)
- Issue Display:
- Volume 25, Issue 5 (2019)
- Year:
- 2019
- Volume:
- 25
- Issue:
- 5
- Issue Sort Value:
- 2019-0025-0005-0000
- Page Start:
- 589
- Page End:
- 595
- Publication Date:
- 2019-10
- Subjects:
- Cerebral angiography -- dose reduction -- image quality compensation -- radiation dose -- radiation exposure
Nervous system -- Interventional radiology -- Periodicals
Nervous system -- Radiography -- Periodicals
Nervous System Diseases -- Periodicals -- radiography
Neuroradiography -- Periodicals
Radiography, Interventional -- Periodicals
Nervous system -- Radiography
Periodicals
617.4805 - Journal URLs:
- http://ine.sagepub.com/ ↗
http://web.ebscohost.com ↗
http://www.ncbi.nlm.nih.gov/pmc/journals/1673/ ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/1591019919850302 ↗
- Languages:
- English
- ISSNs:
- 1591-0199
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11467.xml