Balloon-assisted coiling of cerebral aneurysms with the dual-lumen Scepter XC balloon catheter: Experience at two high-volume centers. Issue 4 (August 2019)
- Record Type:
- Journal Article
- Title:
- Balloon-assisted coiling of cerebral aneurysms with the dual-lumen Scepter XC balloon catheter: Experience at two high-volume centers. Issue 4 (August 2019)
- Main Title:
- Balloon-assisted coiling of cerebral aneurysms with the dual-lumen Scepter XC balloon catheter: Experience at two high-volume centers
- Authors:
- Wallace, Adam N
Samaniego, Edgar
Kayan, Yasha
Derdeyn, Colin P
Delgado Almandoz, Josser E
Dandapat, Sudeepta
Fease, Jennifer L
Thomas, Mary
Milner, Anna M
Scholz, Jill M
Ortega-Gutiérrez, Santiago - Abstract:
- Background: The Scepter XC is a dual-lumen balloon catheter that accommodates a 0.014-inch microwire and can be used for balloon-assisted coiling of cerebral aneurysms. We describe our experience with the use of this device. Methods: Two high-volume institution neurointerventional databases were retrospectively reviewed for cerebral aneurysms treated with balloon-assisted coiling using the Scepter XC balloon catheter. Patient demographics, aneurysm characteristics, and procedural details were recorded. Major procedure-related neurologic complications were defined as events that caused an increase in modified Rankin Scale that persisted for more than 1 week after the procedure. Follow-up aneurysm occlusion was assessed using the Raymond-Roy classification. Results: During the study period, 231 aneurysms were treated in 219 patients (152 women, 67 men) with a mean age of 58.4 ± 12.2 years. Mean aneurysm size was 6.1 ± 3.1 mm, with a mean neck diameter of 3.1 ± 1.3 mm. In total, 77.5% of aneurysms were wide necked, and 39.8% were treated in the setting of subarachnoid hemorrhage. The major complication rate was 0.9% (2/231) per treated aneurysm, including one stroke and one death related to intraoperative aneurysm rupture. Excluding patients who died, angiographic follow up was available for 85.3% (191/224) of aneurysms. During a mean follow up of 17.4 ± 13.0 months (range, 1.7–66.5 months), Raymond-Roy 1 and 2 occlusion rates were 56.5% (108/191) and 35.6% (68/191),Background: The Scepter XC is a dual-lumen balloon catheter that accommodates a 0.014-inch microwire and can be used for balloon-assisted coiling of cerebral aneurysms. We describe our experience with the use of this device. Methods: Two high-volume institution neurointerventional databases were retrospectively reviewed for cerebral aneurysms treated with balloon-assisted coiling using the Scepter XC balloon catheter. Patient demographics, aneurysm characteristics, and procedural details were recorded. Major procedure-related neurologic complications were defined as events that caused an increase in modified Rankin Scale that persisted for more than 1 week after the procedure. Follow-up aneurysm occlusion was assessed using the Raymond-Roy classification. Results: During the study period, 231 aneurysms were treated in 219 patients (152 women, 67 men) with a mean age of 58.4 ± 12.2 years. Mean aneurysm size was 6.1 ± 3.1 mm, with a mean neck diameter of 3.1 ± 1.3 mm. In total, 77.5% of aneurysms were wide necked, and 39.8% were treated in the setting of subarachnoid hemorrhage. The major complication rate was 0.9% (2/231) per treated aneurysm, including one stroke and one death related to intraoperative aneurysm rupture. Excluding patients who died, angiographic follow up was available for 85.3% (191/224) of aneurysms. During a mean follow up of 17.4 ± 13.0 months (range, 1.7–66.5 months), Raymond-Roy 1 and 2 occlusion rates were 56.5% (108/191) and 35.6% (68/191), respectively. The retreatment rate was 12.6% (24/191). Conclusion: Our experience using the coaxial dual-lumen Scepter XC for balloon-assisted coiling demonstrates acceptable aneurysm occlusion and complication rates. … (more)
- Is Part Of:
- Interventional neuroradiology. Volume 25:Issue 4(2019:Aug.)
- Journal:
- Interventional neuroradiology
- Issue:
- Volume 25:Issue 4(2019:Aug.)
- Issue Display:
- Volume 25, Issue 4 (2019)
- Year:
- 2019
- Volume:
- 25
- Issue:
- 4
- Issue Sort Value:
- 2019-0025-0004-0000
- Page Start:
- 414
- Page End:
- 418
- Publication Date:
- 2019-08
- Subjects:
- Aneurysm -- angiography -- balloon -- coiling -- subarachnoid hemorrhage
Nervous system -- Interventional radiology -- Periodicals
Nervous system -- Radiography -- Periodicals
Nervous System Diseases -- Periodicals -- radiography
Neuroradiography -- Periodicals
Radiography, Interventional -- Periodicals
Nervous system -- Radiography
Periodicals
617.4805 - Journal URLs:
- http://ine.sagepub.com/ ↗
http://web.ebscohost.com ↗
http://www.ncbi.nlm.nih.gov/pmc/journals/1673/ ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/1591019919828677 ↗
- Languages:
- English
- ISSNs:
- 1591-0199
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11465.xml