Initial Clinical Results and In Vitro Testing of the New CGuard MicroNet-Covered "One-Size-Fits-All" Carotid Stent. (August 2019)
- Record Type:
- Journal Article
- Title:
- Initial Clinical Results and In Vitro Testing of the New CGuard MicroNet-Covered "One-Size-Fits-All" Carotid Stent. (August 2019)
- Main Title:
- Initial Clinical Results and In Vitro Testing of the New CGuard MicroNet-Covered "One-Size-Fits-All" Carotid Stent
- Authors:
- Wissgott, Christian
Brandt-Wunderlich, Christoph
Kopetsch, Christoph
Schmidt, Wolfram
Andresen, Reimer - Abstract:
- Purpose: To evaluate a MicroNet-covered stent designed for the carotid artery with the new ability to adjust to different vessel diameters.Materials and Methods: Thirty consecutive patients (mean age 72.1±7.7 years; 26 men) with symptomatic stenosis (86.3%±6.4%) of the internal carotid artery were treated with the new self-adjusting nitinol stent, which has a self-expanding, open-cell design covered by an outer conformable layer (MicroNet). The only stent used was the "One-Size-Fits-All" CGuard stent with lengths of 30 or 40 mm. In bench testing, the chronic outward force of the One-Size-Fits-All stent was determined with a segmented head radial force test device. The stent was deployed directly into the test device at a diameter of 5.0 mm, and the chronic outward force was measured up to 10.0 mm, the maximum expansion of the stent.Results: The stent was successfully implanted in all 30 patients without periprocedural complications, including no neurological events within 30 days. The chronic outward force normalized by stent length demonstrated a near-equivalent radial force outcome: The stent displayed only a minor difference between the minimal radial force at 9.0 mm (0.195 N/mm) and the maximal radial force at 5.5 mm (0.330 N/mm).Conclusion: The new self-adjusting, MicroNet-covered stent has high conformability combined with an almost equivalent radial force at expansion diameters ranging from 5.5 to 9.0 mm. The first clinical results demonstrate that the newPurpose: To evaluate a MicroNet-covered stent designed for the carotid artery with the new ability to adjust to different vessel diameters.Materials and Methods: Thirty consecutive patients (mean age 72.1±7.7 years; 26 men) with symptomatic stenosis (86.3%±6.4%) of the internal carotid artery were treated with the new self-adjusting nitinol stent, which has a self-expanding, open-cell design covered by an outer conformable layer (MicroNet). The only stent used was the "One-Size-Fits-All" CGuard stent with lengths of 30 or 40 mm. In bench testing, the chronic outward force of the One-Size-Fits-All stent was determined with a segmented head radial force test device. The stent was deployed directly into the test device at a diameter of 5.0 mm, and the chronic outward force was measured up to 10.0 mm, the maximum expansion of the stent.Results: The stent was successfully implanted in all 30 patients without periprocedural complications, including no neurological events within 30 days. The chronic outward force normalized by stent length demonstrated a near-equivalent radial force outcome: The stent displayed only a minor difference between the minimal radial force at 9.0 mm (0.195 N/mm) and the maximal radial force at 5.5 mm (0.330 N/mm).Conclusion: The new self-adjusting, MicroNet-covered stent has high conformability combined with an almost equivalent radial force at expansion diameters ranging from 5.5 to 9.0 mm. The first clinical results demonstrate that the new One-Size-Fits-All stent can be safely implanted in internal carotid arteries with reference diameters within this range. … (more)
- Is Part Of:
- Journal of endovascular therapy. Volume 26:Number 4(2019:Aug.)
- Journal:
- Journal of endovascular therapy
- Issue:
- Volume 26:Number 4(2019:Aug.)
- Issue Display:
- Volume 26, Issue 4 (2019)
- Year:
- 2019
- Volume:
- 26
- Issue:
- 4
- Issue Sort Value:
- 2019-0026-0004-0000
- Page Start:
- 578
- Page End:
- 582
- Publication Date:
- 2019-08
- Subjects:
- carotid artery stenting -- conformability -- embolic prevention stent -- internal carotid artery -- in vitro testing -- mesh stent -- nitinol -- one-size-fits-all stent -- open-cell stent -- radial force -- stenosis -- stroke
Blood-vessels -- Endoscopic surgery -- Periodicals
Angioscopy -- Periodicals
Intravenous catheterization -- Periodicals
Peripheral vascular diseases -- Treatment -- Periodicals
Vascular Surgical Procedures -- Periodicals
Angioscopy -- Periodicals
Catheterization, Peripheral -- Periodicals
Peripheral Vascular Diseases -- therapy -- Periodicals
Angioscopie
Maladies vasculaires périphériques
617.413 - Journal URLs:
- http://jet.sagepub.com/ ↗
http://www.jevt.org ↗
http://www.uk.sagepub.com ↗ - DOI:
- 10.1177/1526602819849078 ↗
- Languages:
- English
- ISSNs:
- 1526-6028
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11450.xml