Human breath metabolomics using an optimized non-invasive exhaled breath condensate sampler. (22nd December 2016)
- Record Type:
- Journal Article
- Title:
- Human breath metabolomics using an optimized non-invasive exhaled breath condensate sampler. (22nd December 2016)
- Main Title:
- Human breath metabolomics using an optimized non-invasive exhaled breath condensate sampler
- Authors:
- Zamuruyev, Konstantin O
Aksenov, Alexander A
Pasamontes, Alberto
Brown, Joshua F
Pettit, Dayna R
Foutouhi, Soraya
Weimer, Bart C
Schivo, Michael
Kenyon, Nicholas J
Delplanque, Jean-Pierre
Davis, Cristina E - Abstract:
- Abstract: Exhaled breath condensate (EBC) analysis is a developing field with tremendous promise to advance personalized, non-invasive health diagnostics as new analytical instrumentation platforms and detection methods are developed. Multiple commercially-available and researcher-built experimental samplers are reported in the literature. However, there is very limited information available to determine an effective breath sampling approach, especially regarding the dependence of breath sample metabolomic content on the collection device design and sampling methodology. This lack of an optimal standard procedure results in a range of reported results that are sometimes contradictory. Here, we present a design of a portable human EBC sampler optimized for collection and preservation of the rich metabolomic content of breath. The performance of the engineered device is compared to two commercially available breath collection devices: the RTube ™ and TurboDECCS. A number of design and performance parameters are considered, including: condenser temperature stability during sampling, collection efficiency, condenser material choice, and saliva contamination in the collected breath samples. The significance of the biological content of breath samples, collected with each device, is evaluated with a set of mass spectrometry methods and was the primary factor for evaluating device performance. The design includes an adjustable mass-size threshold for aerodynamic filtering of salivaAbstract: Exhaled breath condensate (EBC) analysis is a developing field with tremendous promise to advance personalized, non-invasive health diagnostics as new analytical instrumentation platforms and detection methods are developed. Multiple commercially-available and researcher-built experimental samplers are reported in the literature. However, there is very limited information available to determine an effective breath sampling approach, especially regarding the dependence of breath sample metabolomic content on the collection device design and sampling methodology. This lack of an optimal standard procedure results in a range of reported results that are sometimes contradictory. Here, we present a design of a portable human EBC sampler optimized for collection and preservation of the rich metabolomic content of breath. The performance of the engineered device is compared to two commercially available breath collection devices: the RTube ™ and TurboDECCS. A number of design and performance parameters are considered, including: condenser temperature stability during sampling, collection efficiency, condenser material choice, and saliva contamination in the collected breath samples. The significance of the biological content of breath samples, collected with each device, is evaluated with a set of mass spectrometry methods and was the primary factor for evaluating device performance. The design includes an adjustable mass-size threshold for aerodynamic filtering of saliva droplets from the breath flow. Engineering an inexpensive device that allows efficient collection of metalomic-rich breath samples is intended to aid further advancement in the field of breath analysis for non-invasive health diagnostic. EBC sampling from human volunteers was performed under UC Davis IRB protocol 63701-3 (09/30/2014–07/07/2017). … (more)
- Is Part Of:
- Journal of breath research. Volume 11:Number 1(2017:Mar.)
- Journal:
- Journal of breath research
- Issue:
- Volume 11:Number 1(2017:Mar.)
- Issue Display:
- Volume 11, Issue 1 (2017)
- Year:
- 2017
- Volume:
- 11
- Issue:
- 1
- Issue Sort Value:
- 2017-0011-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-12-22
- Subjects:
- exhaled breath condensate (EBC) -- volatile organic compounds (VOCs) -- non-volatile organic compounds (non-VOCs) -- breath analysis -- metabolomics -- portable non-invasive health diagnostic
Volatile organic compounds -- Analysis -- Periodicals
Clinical chemistry -- Periodicals
Bad breath -- Periodicals
Bad breath -- Treatment -- Periodicals
Bad breath -- Diagnosis -- Periodicals
616.0756 - Journal URLs:
- http://iopscience.iop.org/1752-7163/ ↗
http://ioppublishing.org/ ↗ - DOI:
- 10.1088/1752-7163/11/1/016001 ↗
- Languages:
- English
- ISSNs:
- 1752-7155
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11461.xml