Comparing rib cortical thickness measurements from computed tomography (CT) and Micro-CT. (August 2019)
- Record Type:
- Journal Article
- Title:
- Comparing rib cortical thickness measurements from computed tomography (CT) and Micro-CT. (August 2019)
- Main Title:
- Comparing rib cortical thickness measurements from computed tomography (CT) and Micro-CT
- Authors:
- Hostetler, Zachary S.
Stitzel, Joel D.
Weaver, Ashley A. - Abstract:
- Abstract: Background: The objective of this study was to compare cortical thickness of rib specimens scanned with clinical computed tomography (clinical-CT) at 0.5 and 1.0 mm slice thickness versus micro-CT at 0.05 mm slice thickness. Cortical thickness variation and accuracy was explored by anatomical region (anterior vs. lateral) and cross-sectional quadrants (superior, interior, inferior, and exterior). Methods: A validated cortical thickness algorithm was applied to clinical-CT and micro-CT scans of 17 rib specimens from six male post mortem human subjects aged 42–81 years. Each rib specimen was segmented and the thickness measurements were partitioned into cross-sectional quadrants in the anterior and lateral regions of the rib. Within each rib quadrant, the following were calculated: average thickness ± standard deviation, mean thickness difference between clinical-CT and micro-CT, and a thickness ratio between clinical-CT and micro-CT. Correlations from linear regression and paired-t tests were determined for paired clinical-CT and micro-CT results. Results: On average, the 0.5 mm clinical-CT underestimated the micro-CT thickness by 0.005 mm, while the 1.0 mm clinical-CT overestimated the micro-CT thickness by 0.149 mm. Thickness derived from 0.5 mm clinical-CT showed greater significant linear correlations (p < 0.05) with micro-CT thickness compared to 1.0 mm clinical-CT. Conclusions: The small mean differences and thickness ratios near 1 show validation for theAbstract: Background: The objective of this study was to compare cortical thickness of rib specimens scanned with clinical computed tomography (clinical-CT) at 0.5 and 1.0 mm slice thickness versus micro-CT at 0.05 mm slice thickness. Cortical thickness variation and accuracy was explored by anatomical region (anterior vs. lateral) and cross-sectional quadrants (superior, interior, inferior, and exterior). Methods: A validated cortical thickness algorithm was applied to clinical-CT and micro-CT scans of 17 rib specimens from six male post mortem human subjects aged 42–81 years. Each rib specimen was segmented and the thickness measurements were partitioned into cross-sectional quadrants in the anterior and lateral regions of the rib. Within each rib quadrant, the following were calculated: average thickness ± standard deviation, mean thickness difference between clinical-CT and micro-CT, and a thickness ratio between clinical-CT and micro-CT. Correlations from linear regression and paired-t tests were determined for paired clinical-CT and micro-CT results. Results: On average, the 0.5 mm clinical-CT underestimated the micro-CT thickness by 0.005 mm, while the 1.0 mm clinical-CT overestimated the micro-CT thickness by 0.149 mm. Thickness derived from 0.5 mm clinical-CT showed greater significant linear correlations (p < 0.05) with micro-CT thickness compared to 1.0 mm clinical-CT. Conclusions: The small mean differences and thickness ratios near 1 show validation for the cortical thickness algorithm when applied to rib clinical-CT scans. Using clinical-CT scans as way to accurately measure rib cortical thickness offers a non-invasive way to analyze millions of CT scans collected each year from males and females of all ages. … (more)
- Is Part Of:
- Computers in biology and medicine. Volume 111(2019)
- Journal:
- Computers in biology and medicine
- Issue:
- Volume 111(2019)
- Issue Display:
- Volume 111, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 111
- Issue:
- 2019
- Issue Sort Value:
- 2019-0111-2019-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-08
- Subjects:
- Thorax -- Ribs -- Cortical thickness -- Age -- Computed tomography -- Micro-CT
Medicine -- Data processing -- Periodicals
Biology -- Data processing -- Periodicals
610.285 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00104825/ ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.compbiomed.2019.103330 ↗
- Languages:
- English
- ISSNs:
- 0010-4825
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3394.880000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11436.xml