Optimal automatic detection of muscle activation intervals. (October 2019)
- Record Type:
- Journal Article
- Title:
- Optimal automatic detection of muscle activation intervals. (October 2019)
- Main Title:
- Optimal automatic detection of muscle activation intervals
- Authors:
- Rashid, Usman
Niazi, Imran Khan
Signal, Nada
Farina, Dario
Taylor, Denise - Abstract:
- Abstract: A significant challenge in surface electromyography (sEMG) is the accurate identification of onsets and offsets of muscle activations. Manual labelling and automatic detection are currently used with varying degrees of reliability, accuracy and time efficiency. Automatic methods still require significant manual input to set the optimal parameters for the detection algorithm. These parameters usually need to be adjusted for each individual, muscle and movement task. We propose a method to automatically identify optimal detection parameters in a minimally supervised way. The proposed method solves an optimisation problem that only requires as input the number of activation bursts in the sEMG in a given time interval. This approach was tested on an extended version of the widely adopted double thresholding algorithm, although the optimisation could be applied to any detection algorithm. sEMG data from 22 healthy participants performing a single (ankle dorsiflexion) and a multi-joint (step on/off) task were used for evaluation. Detection rate, concordance, F1 score as an average of sensitivity and precision, degree of over detection, and degree of under detection were used as performance metrices. The proposed method improved the performance of the double thresholding algorithm in multi-joint movement and had the same performance in single joint movement with respect to the performance of the double thresholding algorithm with task specific global parameters. Moreover,Abstract: A significant challenge in surface electromyography (sEMG) is the accurate identification of onsets and offsets of muscle activations. Manual labelling and automatic detection are currently used with varying degrees of reliability, accuracy and time efficiency. Automatic methods still require significant manual input to set the optimal parameters for the detection algorithm. These parameters usually need to be adjusted for each individual, muscle and movement task. We propose a method to automatically identify optimal detection parameters in a minimally supervised way. The proposed method solves an optimisation problem that only requires as input the number of activation bursts in the sEMG in a given time interval. This approach was tested on an extended version of the widely adopted double thresholding algorithm, although the optimisation could be applied to any detection algorithm. sEMG data from 22 healthy participants performing a single (ankle dorsiflexion) and a multi-joint (step on/off) task were used for evaluation. Detection rate, concordance, F1 score as an average of sensitivity and precision, degree of over detection, and degree of under detection were used as performance metrices. The proposed method improved the performance of the double thresholding algorithm in multi-joint movement and had the same performance in single joint movement with respect to the performance of the double thresholding algorithm with task specific global parameters. Moreover, the proposed method was robust when an error of up to ±10% was introduced in the number of activation bursts in the optimisation phase regardless of the movement. In conclusion, our optimised method has improved the automation of a sEMG detection algorithm which may reduce the time burden associated with current sEMG processing. … (more)
- Is Part Of:
- Journal of electromyography and kinesiology. Volume 48(2019)
- Journal:
- Journal of electromyography and kinesiology
- Issue:
- Volume 48(2019)
- Issue Display:
- Volume 48, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 48
- Issue:
- 2019
- Issue Sort Value:
- 2019-0048-2019-0000
- Page Start:
- 103
- Page End:
- 111
- Publication Date:
- 2019-10
- Subjects:
- Surface electromyography (sEMG) -- Onset detection -- Offset detection -- Extended double thresholding algorithm -- Particle swarm optimisation -- Concordance -- Heuristic optimisation
Electromyography -- Periodicals
Kinesiology -- Periodicals
Electromyography -- Periodicals
Movement -- physiology -- Periodicals
Muscles -- physiology -- Periodicals
Électromyographie -- Périodiques
Cinésiologie -- Périodiques
Electromyography
Kinesiology
Electronic journals
Periodicals
616.740757 - Journal URLs:
- http://www.sciencedirect.com/science/journal/10506411 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/10506411 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jelekin.2019.06.010 ↗
- Languages:
- English
- ISSNs:
- 1050-6411
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4974.855000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11431.xml