Evaluating the dosimetric consequences of MLC leaf positioning errors in dynamic IMRT treatments. Issue 3 (12th February 2019)
- Record Type:
- Journal Article
- Title:
- Evaluating the dosimetric consequences of MLC leaf positioning errors in dynamic IMRT treatments. Issue 3 (12th February 2019)
- Main Title:
- Evaluating the dosimetric consequences of MLC leaf positioning errors in dynamic IMRT treatments
- Authors:
- Agarwal, Arpita
Rastogi, Nikhil
Maria Das, KJ
Yoganathan, SA
Udayakumar, D
Naresh, R
Kumar, Shaleen - Abstract:
- Abstract: Purpose: The purpose of this study was to evaluate the dosimetric impact of multileaf collimator (MLC) positional errors on dynamic intensity-modulated radiotherapy (IMRT) treatments through planning simulation. Secondly the sensitivity of IMRT MatriXX device for detecting the MLC leaf positional errors was also evaluated. Materials and methods: In this study five dynamic IMRT plans, each for brain and head–neck (HN), were retrospectively included. An in-house software was used to introduce random errors (uniform distribution between −2·0 and +2·0 mm) and systematic errors [±0·5, ±0·75, ±1·0 and ±2·0 mm (+: open MLC error and −: close MLC error)]. The error-introduced MLC files were imported into the treatment planning system and new dose distributions were calculated. Furthermore, the dose–volume histogram files of all plans were exported to in-house software for equivalent uniform dose (EUD), tumour control probability and normal tissue complication probability calculations. The error-introduced plans were also delivered on LINAC, and the planar fluences were measured by IMRT MatriXX. Further, 3%/3 mm and 2%/2 mm γ -criteria were used for analysis. Results: In planning simulation study, the impact of random errors was negligible and ΔEUD was <0·5±0·7%, for both brain and HN. The impact of systematic errors was substantial, and on average, the maximum change in EUD for systematic errors (close 2 mm) was −10·7±3·1% for brain and −15·5±2·6% for HN. Conclusions: ItAbstract: Purpose: The purpose of this study was to evaluate the dosimetric impact of multileaf collimator (MLC) positional errors on dynamic intensity-modulated radiotherapy (IMRT) treatments through planning simulation. Secondly the sensitivity of IMRT MatriXX device for detecting the MLC leaf positional errors was also evaluated. Materials and methods: In this study five dynamic IMRT plans, each for brain and head–neck (HN), were retrospectively included. An in-house software was used to introduce random errors (uniform distribution between −2·0 and +2·0 mm) and systematic errors [±0·5, ±0·75, ±1·0 and ±2·0 mm (+: open MLC error and −: close MLC error)]. The error-introduced MLC files were imported into the treatment planning system and new dose distributions were calculated. Furthermore, the dose–volume histogram files of all plans were exported to in-house software for equivalent uniform dose (EUD), tumour control probability and normal tissue complication probability calculations. The error-introduced plans were also delivered on LINAC, and the planar fluences were measured by IMRT MatriXX. Further, 3%/3 mm and 2%/2 mm γ -criteria were used for analysis. Results: In planning simulation study, the impact of random errors was negligible and ΔEUD was <0·5±0·7%, for both brain and HN. The impact of systematic errors was substantial, and on average, the maximum change in EUD for systematic errors (close 2 mm) was −10·7±3·1% for brain and −15·5±2·6% for HN. Conclusions: It can be concluded that the acceptable systematic error was 0·4 mm for brain and 0·3 mm for HN. Furthermore, IMRT MatriXX device was able to detect the MLC errors ≥2 mm in HN and >3 mm errors in brain with 2%/2 mm γ -criteria. … (more)
- Is Part Of:
- Journal of radiotherapy in practice. Volume 18:Issue 3(2019)
- Journal:
- Journal of radiotherapy in practice
- Issue:
- Volume 18:Issue 3(2019)
- Issue Display:
- Volume 18, Issue 3 (2019)
- Year:
- 2019
- Volume:
- 18
- Issue:
- 3
- Issue Sort Value:
- 2019-0018-0003-0000
- Page Start:
- 225
- Page End:
- 231
- Publication Date:
- 2019-02-12
- Subjects:
- IMRT, -- MLC, -- random, -- systematic, -- uncertainties
Radiotherapy -- Periodicals
615.842005 - Journal URLs:
- http://journals.cambridge.org/action/displayJournal?jid=JRP ↗
- DOI:
- 10.1017/S1460396918000705 ↗