Development and optimization of a sensitive TaqMan® real‐time PCR with synthetic homologous extrinsic control for quantitation of Human cytomegalovirus viral load. Issue 9 (8th March 2016)
- Record Type:
- Journal Article
- Title:
- Development and optimization of a sensitive TaqMan® real‐time PCR with synthetic homologous extrinsic control for quantitation of Human cytomegalovirus viral load. Issue 9 (8th March 2016)
- Main Title:
- Development and optimization of a sensitive TaqMan® real‐time PCR with synthetic homologous extrinsic control for quantitation of Human cytomegalovirus viral load
- Authors:
- Slavov, Svetoslav Nanev
Otaguiri, Katia Kaori
de Figueiredo, Glauciane Garcia
Yamamoto, Aparecida Yulie
Mussi‐Pinhata, Marisa Marcia
Kashima, Simone
Covas, Dimas Tadeu - Abstract:
- Abstract : Human cytomegalovirus ( Human herpesvirus 5, HCMV) causes frequent asymptomatic infections in the general population. However, in immunosuppressed patients or congenitally infected infants, HCMV is related to high morbidity and mortality. In such cases, a rapid viral detection is crucial for monitoring the clinical outcome and the antiviral treatment. In this study, we optimized a sensitive biplex TaqMan® real‐time PCR for the simultaneous detection and differentiation of a partial HCMV UL97 sequence and homologous extrinsic control (HEC) in the same tube. HEC was represented by a plasmid containing a modified HCMV sequence retaining the original primer binding sites, while the probe sequence was substituted by a phylogenetically divergent one (chloroplast CF0 subunit plant gene). It was estimated that the optimal HEC concentration, which did not influence the HCMV amplification is 1, 000 copies/reaction. The optimized TaqMan® PCR demonstrated high analytical sensitivity (6.97 copies/reaction, CI = 95%) and specificity (100%). Moreover, the reaction showed adequate precision (repeatability, CV = 0.03; reproducibility, CV = 0.0027) and robustness (no carry‐over or cross‐contamination). The diagnostic sensitivity (100%) and specificity (97.8%) were adequate for the clinical application of the molecular platform. The optimized TaqMan® real‐time PCR is suitable for HCMV detection and quantitation in predisposed patients and monitoring of the applied antiviral therapy.Abstract : Human cytomegalovirus ( Human herpesvirus 5, HCMV) causes frequent asymptomatic infections in the general population. However, in immunosuppressed patients or congenitally infected infants, HCMV is related to high morbidity and mortality. In such cases, a rapid viral detection is crucial for monitoring the clinical outcome and the antiviral treatment. In this study, we optimized a sensitive biplex TaqMan® real‐time PCR for the simultaneous detection and differentiation of a partial HCMV UL97 sequence and homologous extrinsic control (HEC) in the same tube. HEC was represented by a plasmid containing a modified HCMV sequence retaining the original primer binding sites, while the probe sequence was substituted by a phylogenetically divergent one (chloroplast CF0 subunit plant gene). It was estimated that the optimal HEC concentration, which did not influence the HCMV amplification is 1, 000 copies/reaction. The optimized TaqMan® PCR demonstrated high analytical sensitivity (6.97 copies/reaction, CI = 95%) and specificity (100%). Moreover, the reaction showed adequate precision (repeatability, CV = 0.03; reproducibility, CV = 0.0027) and robustness (no carry‐over or cross‐contamination). The diagnostic sensitivity (100%) and specificity (97.8%) were adequate for the clinical application of the molecular platform. The optimized TaqMan® real‐time PCR is suitable for HCMV detection and quantitation in predisposed patients and monitoring of the applied antiviral therapy. J. Med. Virol. 88:1604–1612, 2016 . © 2016 Wiley Periodicals, Inc. … (more)
- Is Part Of:
- Journal of medical virology. Volume 88:Issue 9(2016)
- Journal:
- Journal of medical virology
- Issue:
- Volume 88:Issue 9(2016)
- Issue Display:
- Volume 88, Issue 9 (2016)
- Year:
- 2016
- Volume:
- 88
- Issue:
- 9
- Issue Sort Value:
- 2016-0088-0009-0000
- Page Start:
- 1604
- Page End:
- 1612
- Publication Date:
- 2016-03-08
- Subjects:
- HCMV -- molecular detection -- optimization -- internal controls
Virology -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1096-9071 ↗
http://www.interscience.wiley.com/jpages/0146-6615 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmv.24499 ↗
- Languages:
- English
- ISSNs:
- 0146-6615
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5017.095000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11431.xml