Physical activity detection in patients with intracardiac leadless pacemaker. (25th September 2018)
- Record Type:
- Journal Article
- Title:
- Physical activity detection in patients with intracardiac leadless pacemaker. (25th September 2018)
- Main Title:
- Physical activity detection in patients with intracardiac leadless pacemaker
- Authors:
- Bari, Zsolt
Vamos, Mate
Bogyi, Peter
Reynolds, Dwight
Sheldon, Todd
Fagan, Dedra H.
Duray, Gabor Zoltan - Abstract:
- Abstract: Introduction: The Micra Transcatheter Pacing System provides a rate adaptive pacing using an individually programmable three‐axis accelerometer. We evaluated the short‐ and mid‐term performance of the Micra activity sensor by testing all three available activity vectors during the exercise tests. Methods and Results: Implantation and follow‐up data were prospectively collected from the patients undergoing Micra implantation at our institution. Patients underwent a 5‐minute exercise test for each vector at predischarge (initial testing) and at scheduled in‐office visits (repeat testing). On the basis of measurements of activity counts during the test, vectors were categorized to be adequate (excellent or acceptable) or poor. A total of 278 tests with 818 vector measurements were analyzed in 51 patients during follow‐up (median duration was 18 months). Initial testing revealed the adequate quality of the nominal Vector 1 in 74.5% of the patients. Upon repeated testing at subsequent in‐office visits, Vectors 1 and 3 were comparable (adequate quality in 64.7% vs 68.6% of the patients; P = 0.65) but better compared with Vector 2 (51.0%; P = 0.10 vs Vector 1, P = 0.01 vs Vector 3). In a subgroup of 45 patients programmed to VVIR mode, Vector 1 was selected in 46.7% of the patients after the initial test (Vector 2, 8.9%; Vector 3, 44.4%). Vector change was performed in 10 patients (22.2%) following repeated tests within 3 months of postimplantation. Conclusion: TheAbstract: Introduction: The Micra Transcatheter Pacing System provides a rate adaptive pacing using an individually programmable three‐axis accelerometer. We evaluated the short‐ and mid‐term performance of the Micra activity sensor by testing all three available activity vectors during the exercise tests. Methods and Results: Implantation and follow‐up data were prospectively collected from the patients undergoing Micra implantation at our institution. Patients underwent a 5‐minute exercise test for each vector at predischarge (initial testing) and at scheduled in‐office visits (repeat testing). On the basis of measurements of activity counts during the test, vectors were categorized to be adequate (excellent or acceptable) or poor. A total of 278 tests with 818 vector measurements were analyzed in 51 patients during follow‐up (median duration was 18 months). Initial testing revealed the adequate quality of the nominal Vector 1 in 74.5% of the patients. Upon repeated testing at subsequent in‐office visits, Vectors 1 and 3 were comparable (adequate quality in 64.7% vs 68.6% of the patients; P = 0.65) but better compared with Vector 2 (51.0%; P = 0.10 vs Vector 1, P = 0.01 vs Vector 3). In a subgroup of 45 patients programmed to VVIR mode, Vector 1 was selected in 46.7% of the patients after the initial test (Vector 2, 8.9%; Vector 3, 44.4%). Vector change was performed in 10 patients (22.2%) following repeated tests within 3 months of postimplantation. Conclusion: The three‐axis accelerometer‐based rate adaptive pacing feature proved to be feasible after manual selection of an adequate activity vector. Vector testing in Micra patients with chronotropic incompetence appears to be beneficial compared with the use of nominal Vector 1. … (more)
- Is Part Of:
- Journal of cardiovascular electrophysiology. Volume 29:Number 12(2018)
- Journal:
- Journal of cardiovascular electrophysiology
- Issue:
- Volume 29:Number 12(2018)
- Issue Display:
- Volume 29, Issue 12 (2018)
- Year:
- 2018
- Volume:
- 29
- Issue:
- 12
- Issue Sort Value:
- 2018-0029-0012-0000
- Page Start:
- 1690
- Page End:
- 1696
- Publication Date:
- 2018-09-25
- Subjects:
- three‐axis accelerometer -- intracardiac pacemaker -- leadless pacemaker -- Micra pacemaker -- rate adaptive pacing -- rate response
Blood vessels -- Physiology -- Periodicals
Electrophysiology -- Periodicals
Heart -- Physiology -- Periodicals
612.1 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/jce.13729 ↗
- Languages:
- English
- ISSNs:
- 1045-3873
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.866000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11435.xml