Assessment of the Breakaway Torque at the Posterior Pelvic Ring in Human Cadavers. (2nd November 2015)
- Record Type:
- Journal Article
- Title:
- Assessment of the Breakaway Torque at the Posterior Pelvic Ring in Human Cadavers. (2nd November 2015)
- Main Title:
- Assessment of the Breakaway Torque at the Posterior Pelvic Ring in Human Cadavers
- Authors:
- Bastian, Johannes Dominik
Bergmann, Mathias
Schwyn, Ronald
Keel, Marius Johann Baptist
Benneker, Lorin Michael - Abstract:
- ABSTRACT: Purpose : To enhance the diminished screw purchase in cancellous, osteoporotic bone following the fixation of posterior pelvic ring injuries by iliosacral screws an increased bone-implant contact area using modificated screws, techniques or bone cement may become necessary. The aim of the study was to identify sites within the pathway of iliosacral screws requiring modifications of the local bone or the design of instrumentations placed at this site. Materials and Methods : The breakaway torque was measured mechanically at the iliosacral joint ("ISJ"), the sacral lateral mass ("SLM") and the center of the S1 ("CS1"), at a superior and an inferior site under fluoroscopic control on five human cadaveric specimens (3 female; mean age 87 years, range: 76–99) using the DensiProbe™Spine device. Results : The measured median (range) breakaway torque was 0.63 Nm (0.31–2.52) at the "iliosacral joint", 0.14 Nm (0.05–1.22) at the "sacral lateral mass", 0.57 Nm (0.05–1.42) at the "S1 center." The "sacral lateral mass" breakaway torque was lower than compared to that at the "iliosacral joint" ( p < .001) or "S1 center" ( p < .001). The median (range) breakaway torque measured at all superior measurement points was 0.52 Nm (0.10–2.52), and 0.48 Nm (0.05–1.18) at all inferior sites. The observed difference was statistically significant ( p < .05). Conclusions : The lateral mass of the sacrum provides the lowest bone quality for implant anchorage. Iliosacral screws should beABSTRACT: Purpose : To enhance the diminished screw purchase in cancellous, osteoporotic bone following the fixation of posterior pelvic ring injuries by iliosacral screws an increased bone-implant contact area using modificated screws, techniques or bone cement may become necessary. The aim of the study was to identify sites within the pathway of iliosacral screws requiring modifications of the local bone or the design of instrumentations placed at this site. Materials and Methods : The breakaway torque was measured mechanically at the iliosacral joint ("ISJ"), the sacral lateral mass ("SLM") and the center of the S1 ("CS1"), at a superior and an inferior site under fluoroscopic control on five human cadaveric specimens (3 female; mean age 87 years, range: 76–99) using the DensiProbe™Spine device. Results : The measured median (range) breakaway torque was 0.63 Nm (0.31–2.52) at the "iliosacral joint", 0.14 Nm (0.05–1.22) at the "sacral lateral mass", 0.57 Nm (0.05–1.42) at the "S1 center." The "sacral lateral mass" breakaway torque was lower than compared to that at the "iliosacral joint" ( p < .001) or "S1 center" ( p < .001). The median (range) breakaway torque measured at all superior measurement points was 0.52 Nm (0.10–2.52), and 0.48 Nm (0.05–1.18) at all inferior sites. The observed difference was statistically significant ( p < .05). Conclusions : The lateral mass of the sacrum provides the lowest bone quality for implant anchorage. Iliosacral screws should be placed as superior as safely possible, should bridge the iliosacral joint and may allow for cement application at the lateral mass of the sacrum through perforations. … (more)
- Is Part Of:
- Journal of investigative surgery. Volume 28:Number 6(2015:Dec.)
- Journal:
- Journal of investigative surgery
- Issue:
- Volume 28:Number 6(2015:Dec.)
- Issue Display:
- Volume 28, Issue 6 (2015)
- Year:
- 2015
- Volume:
- 28
- Issue:
- 6
- Issue Sort Value:
- 2015-0028-0006-0000
- Page Start:
- 328
- Page End:
- 333
- Publication Date:
- 2015-11-02
- Subjects:
- Posterior pelvic ring -- DensiProbeTM -- osteoporosis -- sacrum -- fragility fracture -- breakaway torque
Surgery -- Research -- Periodicals
Research
Surgery
Surgical Procedures, Operative
617.075 - Journal URLs:
- http://informahealthcare.com/loi/ivs ↗
http://informahealthcare.com ↗ - DOI:
- 10.3109/08941939.2015.1016249 ↗
- Languages:
- English
- ISSNs:
- 0894-1939
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5008.020000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11399.xml