Quality and comfort in head and neck hyperthermia: A redesign according to clinical experience and simulation studies. (17th November 2015)
- Record Type:
- Journal Article
- Title:
- Quality and comfort in head and neck hyperthermia: A redesign according to clinical experience and simulation studies. (17th November 2015)
- Main Title:
- Quality and comfort in head and neck hyperthermia: A redesign according to clinical experience and simulation studies
- Authors:
- Rijnen, Zef
Togni, Paolo
Roskam, Roel
van de Geer, Stefan G.
Goossens, Richard H.M.
Paulides, Margarethus M. - Abstract:
- Abstract: Purpose : Clinical phase III trials have shown the benefit of adding hyperthermia to radiotherapy and chemotherapy for head and neck cancer (H&N). The HYPERcollar, a functional prototype capable of applying hyperthermia to the entire H&N region was developed. Specific absorption rate-based hyperthermia treatment planning (HTP) is used to optimise HYPERcollar treatments. Hence, besides treatment quality, reproduction and reproducibility of the HTP are also pivotal. In the current work we analysed the impact of key parameters on treatment quality and completely redesigned the mechanical layout of the HYPERcollar for improved treatment quality and patient comfort. Material and methods : The requirements regarding patient position and the water bolus shape were quantified by simulation studies. The complete mechanical redesign was based on these requirements and non-modellable improvements were experimentally validated. Results : From simulation studies we imposed the required positioning accuracy to be within ±5 mm. Simulation studies also showed that the water bolus shape has an important impact on treatment quality. Solutions to meet the requirements were 1) a redesign of the applicator, 2) a redesign of the water bolus, and 3) a renewed positioning strategy. Experiments were used to demonstrate whether the solutions meet the requirements. Conclusions : The HYPERcollar redesign improves water bolus shape, stability and skin contact. The renewed positioning strategyAbstract: Purpose : Clinical phase III trials have shown the benefit of adding hyperthermia to radiotherapy and chemotherapy for head and neck cancer (H&N). The HYPERcollar, a functional prototype capable of applying hyperthermia to the entire H&N region was developed. Specific absorption rate-based hyperthermia treatment planning (HTP) is used to optimise HYPERcollar treatments. Hence, besides treatment quality, reproduction and reproducibility of the HTP are also pivotal. In the current work we analysed the impact of key parameters on treatment quality and completely redesigned the mechanical layout of the HYPERcollar for improved treatment quality and patient comfort. Material and methods : The requirements regarding patient position and the water bolus shape were quantified by simulation studies. The complete mechanical redesign was based on these requirements and non-modellable improvements were experimentally validated. Results : From simulation studies we imposed the required positioning accuracy to be within ±5 mm. Simulation studies also showed that the water bolus shape has an important impact on treatment quality. Solutions to meet the requirements were 1) a redesign of the applicator, 2) a redesign of the water bolus, and 3) a renewed positioning strategy. Experiments were used to demonstrate whether the solutions meet the requirements. Conclusions : The HYPERcollar redesign improves water bolus shape, stability and skin contact. The renewed positioning strategy allows for positioning of the patient within the required precision of ±5 mm. By clinically introducing the new design, we aim at improving not only treatment quality and reproducibility, but also patient comfort and operator handling, which are all important for a better hyperthermia treatment quality. … (more)
- Is Part Of:
- International journal of hyperthermia. Volume 31:Number 8(2015)
- Journal:
- International journal of hyperthermia
- Issue:
- Volume 31:Number 8(2015)
- Issue Display:
- Volume 31, Issue 8 (2015)
- Year:
- 2015
- Volume:
- 31
- Issue:
- 8
- Issue Sort Value:
- 2015-0031-0008-0000
- Page Start:
- 823
- Page End:
- 830
- Publication Date:
- 2015-11-17
- Subjects:
- Electromagnetism -- heat transfer modelling -- radiofrequency/microwave -- treatment planning/treatment optimization
Thermotherapy -- Periodicals
615.832 - Journal URLs:
- http://informahealthcare.com/loi/hth ↗
http://www.tandf.co.uk/journals/titles/02656736.asp ↗
http://informahealthcare.com ↗ - DOI:
- 10.3109/02656736.2015.1076893 ↗
- Languages:
- English
- ISSNs:
- 0265-6736
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.297000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11396.xml