Evaluation of a newly developed quantitative heart-type fatty acid binding protein assay based on fluorescence immunochromatography using specific monoclonal antibodies. (17th November 2015)
- Record Type:
- Journal Article
- Title:
- Evaluation of a newly developed quantitative heart-type fatty acid binding protein assay based on fluorescence immunochromatography using specific monoclonal antibodies. (17th November 2015)
- Main Title:
- Evaluation of a newly developed quantitative heart-type fatty acid binding protein assay based on fluorescence immunochromatography using specific monoclonal antibodies
- Authors:
- Kang, Keren
Wu, Peidian
Li, Wenmei
Tang, Shixing
Wang, Jihua
Luo, Xiaochun
Xie, Mingquan - Abstract:
- Abstract : Objectives. To develop a rapid, sensitive and specific assay for quantification of serum heart-type fatty acid binding protein (H-FABP) based on immunofluorescence of specific monoclonal antibodies. Design and Methods. We generated novel H-FABP-directed monoclonal antibodies by cloning of spleen cells of mice immunized with H-FABP. Epitopes were mapped and antigen affinity was assessed by surface plasmon resonance (SPR). The H-FABP specific monoclonal antibodies were coupled to fluorescent beads and sprayed onto a nitrocellulose membrane facilitating quantification of H-FABP by immunofluorescence. Reagent cross-reactivity, interference resistance, accuracy and sensitivity were examined. A total of 103 clinical samples were used to compare the sensitivity and specificity of the new assay to a commercially available Randox kit. Results. This new assay could be finished within 15 min, with sensitivity reaching 1 ng/ml. In a trial of 103 clinical serum samples, the new testing kit results were highly correlated with those from the Randox kit (R 2 = 0.9707). Using the Randox kit as the reference kit, the sensitivity of the new assay was 98.25%, and specificity was 100%. Conclusions. An immunofluorescence-based H-FABP assay employing novel monoclonal antibodies could rapidly, specifically and sensitively detect H-FABP in serum samples, providing an effective method for rapid clinical assessment of H-FABP index in the clinic.
- Is Part Of:
- Scandinavian journal of clinical & laboratory investigation. Volume 75:Number 8(2015)
- Journal:
- Scandinavian journal of clinical & laboratory investigation
- Issue:
- Volume 75:Number 8(2015)
- Issue Display:
- Volume 75, Issue 8 (2015)
- Year:
- 2015
- Volume:
- 75
- Issue:
- 8
- Issue Sort Value:
- 2015-0075-0008-0000
- Page Start:
- 693
- Page End:
- 698
- Publication Date:
- 2015-11-17
- Subjects:
- Myocardial reperfusion injury -- point-of-care testing -- H-FABP -- immunochromatography -- molecular diagnostics
Clinical biochemistry -- Periodicals
Physiology, Pathological -- Periodicals
Physiology, Experimental -- Periodicals
Medicine -- Research -- Periodicals
Clinical medicine -- Periodicals
616.0072 - Journal URLs:
- http://informahealthcare.com/loi/clb ↗
http://informahealthcare.com ↗ - DOI:
- 10.3109/00365513.2015.1054870 ↗
- Languages:
- English
- ISSNs:
- 0036-5513
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8087.500000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11403.xml