Quality Assurance of Spirometry in a Population-Based Study –Predictors of Good Outcome in Spirometry Testing. (1st April 2014)
- Record Type:
- Journal Article
- Title:
- Quality Assurance of Spirometry in a Population-Based Study –Predictors of Good Outcome in Spirometry Testing. (1st April 2014)
- Main Title:
- Quality Assurance of Spirometry in a Population-Based Study –Predictors of Good Outcome in Spirometry Testing
- Authors:
- Tan, Wan C.
Bourbeau, Jean
O'Donnell, Denis
Aaron, Shawn
Maltais, Francois
Marciniuk, Darcy
Hernandez, Paul
Cowie, Robert
Chapman, Kenneth
Sonia Buist, A.
Sin, Don
Mark Fitzgerald, J. - Abstract:
- Abstract: Background: The assurance of high-quality spirometry testing remains a challenge. Methods: Spirometry training consisted of standardized coaching followed by certification for 35 spirometry-naïve and 9 spirometry-experienced research assistants. Spirometry was performed before and after bronchodilator (BD) in random population samples of 5176 people aged 40 years and older from 9 sites in Canada. using the hand-held EasyOne spirometer (ndd Medical Technologies Inc., Andover, MA, USA). Pulmonary function quality assurance with over reading was conducted centrally in Vancouver: spirograms were reviewed and graded according to ATS/ERS standards with prompt feedback to the technician at each site. Descriptive statistics were calculated for manoeuvre acceptability and repeatability variables. A logistic regression model was constructed for the predictors of spirometry quality success. Results: 95% of test sessions achieved pre-determined quality standards for back extrapolated volume (BEV), time to peak flow (PEFT) and end of test volume (EOTV). The mean forced expiratory time (FET) was 11.2 seconds. Then, 90% and 95% of all manoeuvres had FEV1 and FVC that were repeatable within 150 ml and 200 ml respectively. Test quality was slightly better for post-BD test sessions compared with pre-BD for both groups of research assistants. Independent predictors of acceptable test quality included participant characteristics: female sex, younger age, greater BD responsiveness; butAbstract: Background: The assurance of high-quality spirometry testing remains a challenge. Methods: Spirometry training consisted of standardized coaching followed by certification for 35 spirometry-naïve and 9 spirometry-experienced research assistants. Spirometry was performed before and after bronchodilator (BD) in random population samples of 5176 people aged 40 years and older from 9 sites in Canada. using the hand-held EasyOne spirometer (ndd Medical Technologies Inc., Andover, MA, USA). Pulmonary function quality assurance with over reading was conducted centrally in Vancouver: spirograms were reviewed and graded according to ATS/ERS standards with prompt feedback to the technician at each site. Descriptive statistics were calculated for manoeuvre acceptability and repeatability variables. A logistic regression model was constructed for the predictors of spirometry quality success. Results: 95% of test sessions achieved pre-determined quality standards for back extrapolated volume (BEV), time to peak flow (PEFT) and end of test volume (EOTV). The mean forced expiratory time (FET) was 11.2 seconds. Then, 90% and 95% of all manoeuvres had FEV1 and FVC that were repeatable within 150 ml and 200 ml respectively. Test quality was slightly better for post-BD test sessions compared with pre-BD for both groups of research assistants. Independent predictors of acceptable test quality included participant characteristics: female sex, younger age, greater BD responsiveness; but not study site or prior experience in completing spirometry by the technologist. Conclusions: Good quality spirometry tests are attainable in large multicenter epidemiological studies by trained research assistants, irrespective of their prior experience in spirometry. … (more)
- Is Part Of:
- COPD. Volume 11:Number 2(2014:Apr.)
- Journal:
- COPD
- Issue:
- Volume 11:Number 2(2014:Apr.)
- Issue Display:
- Volume 11, Issue 2 (2014)
- Year:
- 2014
- Volume:
- 11
- Issue:
- 2
- Issue Sort Value:
- 2014-0011-0002-0000
- Page Start:
- 143
- Page End:
- 151
- Publication Date:
- 2014-04-01
- Subjects:
- Lung function testing -- primary care -- community -- epidemiology -- technologist experience
Lungs -- Diseases, Obstructive -- Periodicals
616.24 - Journal URLs:
- http://informahealthcare.com/journal/cop ↗
http://informahealthcare.com ↗ - DOI:
- 10.3109/15412555.2013.822857 ↗
- Languages:
- English
- ISSNs:
- 1541-2555
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3465.850000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11403.xml