Automated choroid segmentation of three-dimensional SD-OCT images by incorporating EDI-OCT images. (May 2018)
- Record Type:
- Journal Article
- Title:
- Automated choroid segmentation of three-dimensional SD-OCT images by incorporating EDI-OCT images. (May 2018)
- Main Title:
- Automated choroid segmentation of three-dimensional SD-OCT images by incorporating EDI-OCT images
- Authors:
- Chen, Qiang
Niu, Sijie
Fang, Wangyi
Shuai, Yuanlu
Fan, Wen
Yuan, Songtao
Liu, Qinghuai - Abstract:
- Highlights: We present a novel choroid segmentation strategy for SD-OCT images by incorporating the enhanced depth imaging OCT (EDI-OCT) images. We present a whole registration method between EDI-OCT and SD-OCT images based on retinal thickness and Bruch's Membrane position. Experimental results with 768 images from 6 patients and 210 images from 29 persons demonstrate that our method can achieve high segmentation accuracy for the 3D choroid segmentation of SD-OCT images. Abstract: Background and Objective: The measurement of choroidal volume is more related with eye diseases than choroidal thickness, because the choroidal volume can reflect the diseases comprehensively. The purpose is to automatically segment choroid for three-dimensional (3D) spectral domain optical coherence tomography (SD-OCT) images. Methods: We present a novel choroid segmentation strategy for SD-OCT images by incorporating the enhanced depth imaging OCT (EDI-OCT) images. The down boundary of the choroid, namely choroid-sclera junction (CSJ), is almost invisible in SD-OCT images, while visible in EDI-OCT images. During the SD-OCT imaging, the EDI-OCT images can be generated for the same eye. Thus, we present an EDI-OCT-driven choroid segmentation method for SD-OCT images, where the choroid segmentation results of the EDI-OCT images are used to estimate the average choroidal thickness and to improve the construction of the CSJ feature space of the SD-OCT images. We also present a whole registrationHighlights: We present a novel choroid segmentation strategy for SD-OCT images by incorporating the enhanced depth imaging OCT (EDI-OCT) images. We present a whole registration method between EDI-OCT and SD-OCT images based on retinal thickness and Bruch's Membrane position. Experimental results with 768 images from 6 patients and 210 images from 29 persons demonstrate that our method can achieve high segmentation accuracy for the 3D choroid segmentation of SD-OCT images. Abstract: Background and Objective: The measurement of choroidal volume is more related with eye diseases than choroidal thickness, because the choroidal volume can reflect the diseases comprehensively. The purpose is to automatically segment choroid for three-dimensional (3D) spectral domain optical coherence tomography (SD-OCT) images. Methods: We present a novel choroid segmentation strategy for SD-OCT images by incorporating the enhanced depth imaging OCT (EDI-OCT) images. The down boundary of the choroid, namely choroid-sclera junction (CSJ), is almost invisible in SD-OCT images, while visible in EDI-OCT images. During the SD-OCT imaging, the EDI-OCT images can be generated for the same eye. Thus, we present an EDI-OCT-driven choroid segmentation method for SD-OCT images, where the choroid segmentation results of the EDI-OCT images are used to estimate the average choroidal thickness and to improve the construction of the CSJ feature space of the SD-OCT images. We also present a whole registration method between EDI-OCT and SD-OCT images based on retinal thickness and Bruch's Membrane (BM) position. The CSJ surface is obtained with a 3D graph search in the CSJ feature space. Results: Experimental results with 768 images (6 cubes, 128 B-scan images for each cube) from 2 healthy persons, 2 age-related macular degeneration (AMD) and 2 diabetic retinopathy (DR) patients, and 210 B-scan images from other 8 healthy persons and 21 patients demonstrate that our method can achieve high segmentation accuracy. The mean choroid volume difference and overlap ratio for 6 cubes between our proposed method and outlines drawn by experts were −1.96µm3 and 88.56%, respectively. Conclusions: Our method is effective for the 3D choroid segmentation of SD-OCT images because the segmentation accuracy and stability are compared with the manual segmentation. … (more)
- Is Part Of:
- Computer methods and programs in biomedicine. Volume 158(2018)
- Journal:
- Computer methods and programs in biomedicine
- Issue:
- Volume 158(2018)
- Issue Display:
- Volume 158, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 158
- Issue:
- 2018
- Issue Sort Value:
- 2018-0158-2018-0000
- Page Start:
- 161
- Page End:
- 171
- Publication Date:
- 2018-05
- Subjects:
- Choroid segmentation -- SD-OCT -- EDI-OCT -- Image registration -- 3D graph search
Medicine -- Computer programs -- Periodicals
Biology -- Computer programs -- Periodicals
Computers -- Periodicals
Medicine -- Periodicals
Médecine -- Logiciels -- Périodiques
Biologie -- Logiciels -- Périodiques
Biology -- Computer programs
Medicine -- Computer programs
Periodicals
Electronic journals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01692607 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.cmpb.2017.11.002 ↗
- Languages:
- English
- ISSNs:
- 0169-2607
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3394.095000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File: