Hypoxia positron emission tomography imaging: combining information on perfusion and tracer retention to improve hypoxia specificity. (2nd November 2017)
- Record Type:
- Journal Article
- Title:
- Hypoxia positron emission tomography imaging: combining information on perfusion and tracer retention to improve hypoxia specificity. (2nd November 2017)
- Main Title:
- Hypoxia positron emission tomography imaging: combining information on perfusion and tracer retention to improve hypoxia specificity
- Authors:
- Busk, Morten
Munk, Ole L.
Jakobsen, Steen S.
Horsman, Michael R. - Abstract:
- Abstract: Background: Static positron emission tomography (PET) allows mapping of tumor hypoxia, but low resolution and slow tracer retention/clearance results in poor image contrast and the risk of missing areas where hypoxic cells and necrosis are intermixed. Fully dynamic PET may improve accuracy but scan protocols suitable for routine clinical use are warranted. A modeling study proposed that hypoxia specificity can be improved by a clinically feasible blood-flow normalization procedure that only requires a 10- to 15-min dynamic scan (perfusion), followed by a short late static scan, but experimental validation is desired. Methods: Tumor-bearing mice were administered pimonidazole (hypoxia marker) and the PET hypoxia-tracer 18 F-azomycin arabinoside (FAZA) and scanned for 3h. Subsequently, the distributions of FAZA (autoradiography) and hypoxic cells (pimonidazole) were compared on tissue sections. PET images collected in 10-min time intervals between 60 and 90 min post-injection (PETearly ), which mimics the image contrast seen in patients, were compared voxel-by-voxel to 3-h PET (PETlate ). For comparison, PETearly was normalized to the perfusion peak area, deduced from the first 10 min of the scan (PETperf ), and the resulting parameter PETearly /PETperf was compared with PETlate . Results: Tissue analysis revealed a near-perfect spatial match between FAZA signal and hypoxic cell density (pimonidazole) 3 h post-injection, regardless of the tumor type. Only a weakAbstract: Background: Static positron emission tomography (PET) allows mapping of tumor hypoxia, but low resolution and slow tracer retention/clearance results in poor image contrast and the risk of missing areas where hypoxic cells and necrosis are intermixed. Fully dynamic PET may improve accuracy but scan protocols suitable for routine clinical use are warranted. A modeling study proposed that hypoxia specificity can be improved by a clinically feasible blood-flow normalization procedure that only requires a 10- to 15-min dynamic scan (perfusion), followed by a short late static scan, but experimental validation is desired. Methods: Tumor-bearing mice were administered pimonidazole (hypoxia marker) and the PET hypoxia-tracer 18 F-azomycin arabinoside (FAZA) and scanned for 3h. Subsequently, the distributions of FAZA (autoradiography) and hypoxic cells (pimonidazole) were compared on tissue sections. PET images collected in 10-min time intervals between 60 and 90 min post-injection (PETearly ), which mimics the image contrast seen in patients, were compared voxel-by-voxel to 3-h PET (PETlate ). For comparison, PETearly was normalized to the perfusion peak area, deduced from the first 10 min of the scan (PETperf ), and the resulting parameter PETearly /PETperf was compared with PETlate . Results: Tissue analysis revealed a near-perfect spatial match between FAZA signal and hypoxic cell density (pimonidazole) 3 h post-injection, regardless of the tumor type. Only a weak inverse or no correlation between PETperf and PETlate was seen, and the correlation between PETearly /PETperf and PETlate proved inferior to the correlation between PETearly and PETlate . Conclusions: Late PET scans in rodents, unlike patients, provide an accurate map of hypoxia against which earlier time-point scans can be compared. PETearly and PETlate correlated to a variable extent but the correlation was lowered by normalization to perfusion (PETearly /PETperf ). Our study challenges the validity/robustness of a perfusion normalization approach. This may reflect that the chaotic tumor vasculature uncouples microregional blood flow and oxygen extraction. … (more)
- Is Part Of:
- Acta oncologica. Volume 56:Number 11(2017)
- Journal:
- Acta oncologica
- Issue:
- Volume 56:Number 11(2017)
- Issue Display:
- Volume 56, Issue 11 (2017)
- Year:
- 2017
- Volume:
- 56
- Issue:
- 11
- Issue Sort Value:
- 2017-0056-0011-0000
- Page Start:
- 1583
- Page End:
- 1590
- Publication Date:
- 2017-11-02
- Subjects:
- Oncology -- Periodicals
Cancer -- Treatment -- Periodicals
616.992 - Journal URLs:
- http://informahealthcare.com/loi/onc ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/0284186X.2017.1355114 ↗
- Languages:
- English
- ISSNs:
- 0284-186X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0641.705000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11387.xml