Safety and efficiency of low-field magnetic resonance imaging in patients with cardiac rhythm management devices. Issue 118 (September 2019)
- Record Type:
- Journal Article
- Title:
- Safety and efficiency of low-field magnetic resonance imaging in patients with cardiac rhythm management devices. Issue 118 (September 2019)
- Main Title:
- Safety and efficiency of low-field magnetic resonance imaging in patients with cardiac rhythm management devices
- Authors:
- Schukro, Christoph
Puchner, Stefan B. - Abstract:
- Highlights: Low-field MRI is safe in patients with pacemakers and implantable defibrillators Presence of abandoned leads or pacemaker-dependency revealed no complications Low-field MRI is efficient for routine diagnostic scans of many regions of interest Abstract: Purpose: Low-field magnetic resonance imaging (MRI), i.e. MRI with a static magnetic field strength <0.5 T, has been reported to be safe in patients with pacemakers, however there are no data about the safety of low-field MRI in patients with implantable cardioverter defibrillators (ICD) and/or cardiac resynchronization therapy (CRT). We aimed to investigate the safety and diagnostic efficiency of routine low-field MRI in patients with different devices for cardiac rhythm management (i.e. pacemakers and ICD, including devices with CRT). Method: MRI scans of 446 regions of interest were evaluated with field strength of 0.2 T in 338 patients (62% male; age at MRI scan 76.1 ± 9.2 years; time since device implantation 4.1 ± 3.2 years) with cardiac rhythm management devices (298 pacemakers, 25 ICD, 8 CRT-ICD, and 7 CRT pacemakers). This analysis included 62 pacemaker-dependent patients (18.3%), 52 patients with 1.5-Tesla-MR conditional pacemakers (15.4%) and 13 patients with abandoned leads (3.9%). Results: Except for one examination, which was interrupted because of recurrent severe nausea, all MRI scans could be analyzed efficiently. No induction of arrhythmia or inhibition of pacemaker function occurred. Compared toHighlights: Low-field MRI is safe in patients with pacemakers and implantable defibrillators Presence of abandoned leads or pacemaker-dependency revealed no complications Low-field MRI is efficient for routine diagnostic scans of many regions of interest Abstract: Purpose: Low-field magnetic resonance imaging (MRI), i.e. MRI with a static magnetic field strength <0.5 T, has been reported to be safe in patients with pacemakers, however there are no data about the safety of low-field MRI in patients with implantable cardioverter defibrillators (ICD) and/or cardiac resynchronization therapy (CRT). We aimed to investigate the safety and diagnostic efficiency of routine low-field MRI in patients with different devices for cardiac rhythm management (i.e. pacemakers and ICD, including devices with CRT). Method: MRI scans of 446 regions of interest were evaluated with field strength of 0.2 T in 338 patients (62% male; age at MRI scan 76.1 ± 9.2 years; time since device implantation 4.1 ± 3.2 years) with cardiac rhythm management devices (298 pacemakers, 25 ICD, 8 CRT-ICD, and 7 CRT pacemakers). This analysis included 62 pacemaker-dependent patients (18.3%), 52 patients with 1.5-Tesla-MR conditional pacemakers (15.4%) and 13 patients with abandoned leads (3.9%). Results: Except for one examination, which was interrupted because of recurrent severe nausea, all MRI scans could be analyzed efficiently. No induction of arrhythmia or inhibition of pacemaker function occurred. Compared to the device interrogation before MRI, there were no significant changes in battery voltage, pacing capture threshold, sensing of intrinsic ECG, lead impedance, as well as shock impedance in ICD devices after completed examination. Conclusions: Low-field MRI examinations (0.2 T) were efficient and safe regarding clinical and technical complications in patients with devices for cardiac rhythm management, even in case of pacemaker-dependency or the presence of abandoned leads. … (more)
- Is Part Of:
- European journal of radiology. Issue 118(2019)
- Journal:
- European journal of radiology
- Issue:
- Issue 118(2019)
- Issue Display:
- Volume 118, Issue 118 (2019)
- Year:
- 2019
- Volume:
- 118
- Issue:
- 118
- Issue Sort Value:
- 2019-0118-0118-0000
- Page Start:
- 96
- Page End:
- 100
- Publication Date:
- 2019-09
- Subjects:
- Low-field magnetic resonance imaging -- Implantable cardioverter defibrillator -- Pacemaker -- Cardiac resynchronization therapy -- Safety
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2019.07.005 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11366.xml