Low-dose dynamic myocardial perfusion CT image reconstruction using pre-contrast normal-dose CT scan induced structure tensor total variation regularization. (1st March 2017)
- Record Type:
- Journal Article
- Title:
- Low-dose dynamic myocardial perfusion CT image reconstruction using pre-contrast normal-dose CT scan induced structure tensor total variation regularization. (1st March 2017)
- Main Title:
- Low-dose dynamic myocardial perfusion CT image reconstruction using pre-contrast normal-dose CT scan induced structure tensor total variation regularization
- Authors:
- Gong, Changfei
Han, Ce
Gan, Guanghui
Deng, Zhenxiang
Zhou, Yongqiang
Yi, Jinling
Zheng, Xiaomin
Xie, Congying
Jin, Xiance - Abstract:
- Abstract: Dynamic myocardial perfusion CT (DMP-CT) imaging provides quantitative functional information for diagnosis and risk stratification of coronary artery disease by calculating myocardial perfusion hemodynamic parameter (MPHP) maps. However, the level of radiation delivered by dynamic sequential scan protocol can be potentially high. The purpose of this work is to develop a pre-contrast normal-dose scan induced structure tensor total variation regularization based on the penalized weighted least-squares (PWLS) criteria to improve the image quality of DMP-CT with a low-mAs CT acquisition. For simplicity, the present approach was termed as 'PWLS-ndiSTV'. Specifically, the ndiSTV regularization takes into account the spatial-temporal structure information of DMP-CT data and further exploits the higher order derivatives of the objective images to enhance denoising performance. Subsequently, an effective optimization algorithm based on the split-Bregman approach was adopted to minimize the associative objective function. Evaluations with modified dynamic XCAT phantom and preclinical porcine datasets have demonstrated that the proposed PWLS-ndiSTV approach can achieve promising gains over other existing approaches in terms of noise-induced artifacts mitigation, edge details preservation, and accurate MPHP maps calculation.
- Is Part Of:
- Physics in medicine & biology. Volume 62:Number 7(2017:Apr.)
- Journal:
- Physics in medicine & biology
- Issue:
- Volume 62:Number 7(2017:Apr.)
- Issue Display:
- Volume 62, Issue 7 (2017)
- Year:
- 2017
- Volume:
- 62
- Issue:
- 7
- Issue Sort Value:
- 2017-0062-0007-0000
- Page Start:
- 2612
- Page End:
- 2635
- Publication Date:
- 2017-03-01
- Subjects:
- dynamic myocardial perfusion computed tomography -- myocardial perfusion hemodynamic parameter -- low-mAs -- structure tensor total variation -- regularization
Biophysics -- Periodicals
Medical physics -- Periodicals
610.153 - Journal URLs:
- http://ioppublishing.org/ ↗
http://iopscience.iop.org/0031-9155 ↗ - DOI:
- 10.1088/1361-6560/aa5d40 ↗
- Languages:
- English
- ISSNs:
- 0031-9155
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11334.xml