Impact of physiological noise correction on detecting blood oxygenation level-dependent contrast in the breast. (13th December 2016)
- Record Type:
- Journal Article
- Title:
- Impact of physiological noise correction on detecting blood oxygenation level-dependent contrast in the breast. (13th December 2016)
- Main Title:
- Impact of physiological noise correction on detecting blood oxygenation level-dependent contrast in the breast
- Authors:
- Wallace, Tess E
Manavaki, Roido
Graves, Martin J
Patterson, Andrew J
Gilbert, Fiona J - Abstract:
- Abstract: Physiological fluctuations are expected to be a dominant source of noise in blood oxygenation level-dependent (BOLD) magnetic resonance imaging (MRI) experiments to assess tumour oxygenation and angiogenesis. This work investigates the impact of various physiological noise regressors: retrospective image correction (RETROICOR), heart rate (HR) and respiratory volume per unit time (RVT), on signal variance and the detection of BOLD contrast in the breast in response to a modulated respiratory stimulus. BOLD MRI was performed at 3 T in ten volunteers at rest and during cycles of oxygen and carbogen gas breathing. RETROICOR was optimized using F -tests to determine which cardiac and respiratory phase terms accounted for a significant amount of signal variance. A nested regression analysis was performed to assess the effect of RETROICOR, HR and RVT on the model fit residuals, temporal signal-to-noise ratio, and BOLD activation parameters. The optimized RETROICOR model accounted for the largest amount of signal variance ( Δ R adj 2 = 3.3 ± 2.1%) and improved the detection of BOLD activation ( P = 0.002). Inclusion of HR and RVT regressors explained additional signal variance, but had a negative impact on activation parameter estimation ( P < 0.001). Fluctuations in HR and RVT appeared to be correlated with the stimulus and may contribute to apparent BOLD signal reactivity.
- Is Part Of:
- Physics in medicine & biology. Volume 62:Number 1(2017:Jan.)
- Journal:
- Physics in medicine & biology
- Issue:
- Volume 62:Number 1(2017:Jan.)
- Issue Display:
- Volume 62, Issue 1 (2017)
- Year:
- 2017
- Volume:
- 62
- Issue:
- 1
- Issue Sort Value:
- 2017-0062-0001-0000
- Page Start:
- 127
- Page End:
- 145
- Publication Date:
- 2016-12-13
- Subjects:
- functional magnetic resonance imaging -- physiological noise -- retrospective image correction -- BOLD contrast -- haemodynamic response
Biophysics -- Periodicals
Medical physics -- Periodicals
610.153 - Journal URLs:
- http://ioppublishing.org/ ↗
http://iopscience.iop.org/0031-9155 ↗ - DOI:
- 10.1088/1361-6560/62/1/127 ↗
- Languages:
- English
- ISSNs:
- 0031-9155
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11337.xml