Response profiles of murine spiral ganglion neurons on multi-electrode arrays. (14th December 2015)
- Record Type:
- Journal Article
- Title:
- Response profiles of murine spiral ganglion neurons on multi-electrode arrays. (14th December 2015)
- Main Title:
- Response profiles of murine spiral ganglion neurons on multi-electrode arrays
- Authors:
- Hahnewald, Stefan
Tscherter, Anne
Marconi, Emanuele
Streit, Jürg
Widmer, Hans Rudolf
Garnham, Carolyn
Benav, Heval
Mueller, Marcus
Löwenheim, Hubert
Roccio, Marta
Senn, Pascal - Abstract:
- Abstract: Objective. Cochlear implants (CIs) have become the gold standard treatment for deafness. These neuroprosthetic devices feature a linear electrode array, surgically inserted into the cochlea, and function by directly stimulating the auditory neurons located within the spiral ganglion, bypassing lost or not-functioning hair cells. Despite their success, some limitations still remain, including poor frequency resolution and high-energy consumption. In both cases, the anatomical gap between the electrode array and the spiral ganglion neurons (SGNs) is believed to be an important limiting factor. The final goal of the study is to characterize response profiles of SGNs growing in intimate contact with an electrode array, in view of designing novel CI devices and stimulation protocols, featuring a gapless interface with auditory neurons. Approach. We have characterized SGN responses to extracellular stimulation using multi-electrode arrays (MEAs). This setup allows, in our view, to optimize in vitro many of the limiting interface aspects between CIs and SGNs. Main results. Early postnatal mouse SGN explants were analyzed after 6–18 days in culture. Different stimulation protocols were compared with the aim to lower the stimulation threshold and the energy needed to elicit a response. In the best case, a four-fold reduction of the energy was obtained by lengthening the biphasic stimulus from 40 μ s to 160 μ s. Similarly, quasi monophasic pulses were more effective thanAbstract: Objective. Cochlear implants (CIs) have become the gold standard treatment for deafness. These neuroprosthetic devices feature a linear electrode array, surgically inserted into the cochlea, and function by directly stimulating the auditory neurons located within the spiral ganglion, bypassing lost or not-functioning hair cells. Despite their success, some limitations still remain, including poor frequency resolution and high-energy consumption. In both cases, the anatomical gap between the electrode array and the spiral ganglion neurons (SGNs) is believed to be an important limiting factor. The final goal of the study is to characterize response profiles of SGNs growing in intimate contact with an electrode array, in view of designing novel CI devices and stimulation protocols, featuring a gapless interface with auditory neurons. Approach. We have characterized SGN responses to extracellular stimulation using multi-electrode arrays (MEAs). This setup allows, in our view, to optimize in vitro many of the limiting interface aspects between CIs and SGNs. Main results. Early postnatal mouse SGN explants were analyzed after 6–18 days in culture. Different stimulation protocols were compared with the aim to lower the stimulation threshold and the energy needed to elicit a response. In the best case, a four-fold reduction of the energy was obtained by lengthening the biphasic stimulus from 40 μ s to 160 μ s. Similarly, quasi monophasic pulses were more effective than biphasic pulses and the insertion of an interphase gap moderately improved efficiency. Finally, the stimulation with an external electrode mounted on a micromanipulator showed that the energy needed to elicit a response could be reduced by a factor of five with decreasing its distance from 40 μ m to 0 μ m from the auditory neurons. Significance. This study is the first to show electrical activity of SGNs on MEAs. Our findings may help to improve stimulation by and to reduce energy consumption of CIs and thereby contribute to the development of fully implantable devices with better auditory resolution in the future. … (more)
- Is Part Of:
- Journal of neural engineering. Volume 13:Number 1(2016:Feb.)
- Journal:
- Journal of neural engineering
- Issue:
- Volume 13:Number 1(2016:Feb.)
- Issue Display:
- Volume 13, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 13
- Issue:
- 1
- Issue Sort Value:
- 2016-0013-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-12-14
- Subjects:
- spiral ganglion -- multi-electrode array -- cochlear implant -- electrophysiology -- hearing -- artificial hearing
Neurosciences -- Periodicals
Biomedical engineering -- Periodicals
612.8 - Journal URLs:
- http://iopscience.iop.org/1741-2552/ ↗
http://ioppublishing.org/ ↗ - DOI:
- 10.1088/1741-2560/13/1/016011 ↗
- Languages:
- English
- ISSNs:
- 1741-2560
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11329.xml