Collapse performance of seismically isolated buildings designed by the procedures of ASCE/SEI 7. (1st June 2018)
- Record Type:
- Journal Article
- Title:
- Collapse performance of seismically isolated buildings designed by the procedures of ASCE/SEI 7. (1st June 2018)
- Main Title:
- Collapse performance of seismically isolated buildings designed by the procedures of ASCE/SEI 7
- Authors:
- Kitayama, Shoma
Constantinou, Michael C. - Abstract:
- Highlights: Investigated collapse performance of seismically isolated and non-isolated buildings. Buildings designed by the minimum ASCE 7 criteria and enhanced design criteria. Considered double and triple friction pendulum isolators. Probabilities of collapse in the maximum earthquake were calculated. Recommendations provided for system design to achieve acceptable performance. Abstract: This article presents an analytical study of the seismic collapse performance of seismically isolated buildings and comparable non-isolated buildings. The study is based on archetypical 6-story perimeter frame seismically isolated buildings designed with special concentrically braced frames (SCBF), ordinary concentrically braced frames (OCBF) and special moment resisting frames (SMF) for a location in California using the minimum criteria of ASCE/SEI 7-10 and ASCE/SEI 7-16 and also using a number of enhanced designs. The isolation system consists of triple Friction Pendulum (FP) isolators with stiffening behavior at large displacement. Additionally, double concave sliding isolators are considered and designed per minimum criteria of ASCE/SEI 7 and without a displacement restrainer, a practice permitted by the standards. Non-isolated structures, also with braced and moment frame configurations, are designed using the minimum criteria of ASCE/SEI 7 and studied. The study concludes that seismically isolated buildings designed by the minimum criteria of ASCE/SEI 7 of either 2010 or 2016 mayHighlights: Investigated collapse performance of seismically isolated and non-isolated buildings. Buildings designed by the minimum ASCE 7 criteria and enhanced design criteria. Considered double and triple friction pendulum isolators. Probabilities of collapse in the maximum earthquake were calculated. Recommendations provided for system design to achieve acceptable performance. Abstract: This article presents an analytical study of the seismic collapse performance of seismically isolated buildings and comparable non-isolated buildings. The study is based on archetypical 6-story perimeter frame seismically isolated buildings designed with special concentrically braced frames (SCBF), ordinary concentrically braced frames (OCBF) and special moment resisting frames (SMF) for a location in California using the minimum criteria of ASCE/SEI 7-10 and ASCE/SEI 7-16 and also using a number of enhanced designs. The isolation system consists of triple Friction Pendulum (FP) isolators with stiffening behavior at large displacement. Additionally, double concave sliding isolators are considered and designed per minimum criteria of ASCE/SEI 7 and without a displacement restrainer, a practice permitted by the standards. Non-isolated structures, also with braced and moment frame configurations, are designed using the minimum criteria of ASCE/SEI 7 and studied. The study concludes that seismically isolated buildings designed by the minimum criteria of ASCE/SEI 7 of either 2010 or 2016 may have unacceptable probability of collapse in the Risk-Targeted Maximum Considered Earthquake (MCER ). The probability of collapse in the MCER becomes acceptable when they are designed with enhanced criteria of R I =1.0 and with isolators having a displacement capacity at initiation of stiffening equal to 1.5 times the demand in the MCER . It is also observed that designs that meet the minimum criteria of ASCE/SEI 7 of either 2010 or 2016 and without any displacement restrainer have unacceptably high probabilities of collapse. … (more)
- Is Part Of:
- Engineering structures. Volume 164(2018)
- Journal:
- Engineering structures
- Issue:
- Volume 164(2018)
- Issue Display:
- Volume 164, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 164
- Issue:
- 2018
- Issue Sort Value:
- 2018-0164-2018-0000
- Page Start:
- 243
- Page End:
- 258
- Publication Date:
- 2018-06-01
- Subjects:
- Seismic isolation -- ASCE 7 standard -- Friction pendulum isolator -- Collapse probability -- Risk assessment -- Moment frame -- Braced frame
Structural engineering -- Periodicals
Structural analysis (Engineering) -- Periodicals
Construction, Technique de la -- Périodiques
Génie parasismique -- Périodiques
Pression du vent -- Périodiques
Earthquake engineering
Structural engineering
Wind-pressure
Periodicals
624.105 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01410296 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.engstruct.2018.03.008 ↗
- Languages:
- English
- ISSNs:
- 0141-0296
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3770.032000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11334.xml