Shear performance of a novel demountable steel-concrete bolted connector under static push-out tests. (1st April 2018)
- Record Type:
- Journal Article
- Title:
- Shear performance of a novel demountable steel-concrete bolted connector under static push-out tests. (1st April 2018)
- Main Title:
- Shear performance of a novel demountable steel-concrete bolted connector under static push-out tests
- Authors:
- Yang, Fei
Liu, Yuqing
Jiang, Zhibo
Xin, Haohui - Abstract:
- Highlights: A novel bolted connector with a short bolt, a long bolt and a coupler is proposed. Push-out tests are implemented on four groups of novel bolted connector specimens. The failure mode of novel bolted connector specimens is that the short bolts are sheared off. The shear performance of novel bolted connectors are investigated. Abstract: Bolted connectors could be an alternative to replace conventional welded headed studs between steel girders and concrete slabs, which may benefit prefabricated construction and replacement of concrete slabs considering the life-cycle design of steel-concrete composite structures. In this paper, a novel steel-concrete bolted connector, consisting of a short bolt, a long bolt and a coupler, is proposed. Compared with other bolted connectors, this bolted connector could render the dismantling of concrete slabs more convenient. To investigate the failure mode and fundamental mechanical behaviour of novel bolted connectors and to compare their shear performance with that of conventional welded headed studs, static push-out tests were implemented on four groups of bolted connector specimens and one group of welded stud specimens. The test results demonstrate that the failure mode of novel bolted connectors is that shanks of short bolts are sheared off directly without local concrete crushing phenomenon under couplers. The shear bearing capacity is about 0.8 times of the tensile strength of short bolts, and the peak slip of theHighlights: A novel bolted connector with a short bolt, a long bolt and a coupler is proposed. Push-out tests are implemented on four groups of novel bolted connector specimens. The failure mode of novel bolted connector specimens is that the short bolts are sheared off. The shear performance of novel bolted connectors are investigated. Abstract: Bolted connectors could be an alternative to replace conventional welded headed studs between steel girders and concrete slabs, which may benefit prefabricated construction and replacement of concrete slabs considering the life-cycle design of steel-concrete composite structures. In this paper, a novel steel-concrete bolted connector, consisting of a short bolt, a long bolt and a coupler, is proposed. Compared with other bolted connectors, this bolted connector could render the dismantling of concrete slabs more convenient. To investigate the failure mode and fundamental mechanical behaviour of novel bolted connectors and to compare their shear performance with that of conventional welded headed studs, static push-out tests were implemented on four groups of bolted connector specimens and one group of welded stud specimens. The test results demonstrate that the failure mode of novel bolted connectors is that shanks of short bolts are sheared off directly without local concrete crushing phenomenon under couplers. The shear bearing capacity is about 0.8 times of the tensile strength of short bolts, and the peak slip of the steel-concrete interface grows as the bolt shank diameter increases. The exponential expression which generally describes load-slip curves of welded stud connectors simulates the test load-slip curves of novel bolted connectors well. The clearance between bolt shank and bolt hole has a significant effect on the shear stiffness of novel bolted connectors. … (more)
- Is Part Of:
- Engineering structures. Volume 160(2018)
- Journal:
- Engineering structures
- Issue:
- Volume 160(2018)
- Issue Display:
- Volume 160, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 160
- Issue:
- 2018
- Issue Sort Value:
- 2018-0160-2018-0000
- Page Start:
- 133
- Page End:
- 146
- Publication Date:
- 2018-04-01
- Subjects:
- Steel-concrete composite structure -- Demountable bolted connector -- Push-out test -- Shear bearing capacity -- Load-slip curve -- Shear stiffness
Structural engineering -- Periodicals
Structural analysis (Engineering) -- Periodicals
Construction, Technique de la -- Périodiques
Génie parasismique -- Périodiques
Pression du vent -- Périodiques
Earthquake engineering
Structural engineering
Wind-pressure
Periodicals
624.105 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01410296 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.engstruct.2018.01.005 ↗
- Languages:
- English
- ISSNs:
- 0141-0296
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3770.032000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11327.xml