A control system for preventing cavitation of centrifugal pumps. (August 2018)
- Record Type:
- Journal Article
- Title:
- A control system for preventing cavitation of centrifugal pumps. (August 2018)
- Main Title:
- A control system for preventing cavitation of centrifugal pumps
- Authors:
- Cucit, Valentino
Burlon, Fabio
Fenu, Gianfranco
Furlanetto, Riccardo
Pellegrino, Felice Andrea
Simonato, Michele - Abstract:
- Abstract: Cavitation is a well-known phenomenon that may occur, among other turbo-machines, in centrifugal pumps and can result in severe damage of both the pump and the whole hydraulic system. There are situations in which, in principle, the cavitation could be avoided by detecting the condition of incipient cavitation, and changing slightly the working point of the whole system in order to move away from that condition. In the present paper two simple closed-loop control strategies are implemented, acting on the pump's rotational speed and fed by the measurements of a set of inertial sensors. In particular, the research is focused on a centrifugal pump normally employed in hydraulic systems. The pump operates in a dedicated test rig, where cavitation can be induced by acting on a reservoir's pressure. Three accelerometers are installed in the pump body along three orthogonal axes. An extensive set of experiments has been carried out at different flow rates and a number of signals' features both in the time domain and in the frequency domain have been considered as indicators of incipient cavitation. The amount of energy of the signal captured by the accelerometer in the component orthogonal to the flow direction, in the band from 10 to 12.8 kHz, demonstrated to be effective in detecting the incipient cavitation, by selecting a proper (condition-dependent) threshold. Therefore, two simple controllers have been designed: the first regulates the speed of the pump, to recoverAbstract: Cavitation is a well-known phenomenon that may occur, among other turbo-machines, in centrifugal pumps and can result in severe damage of both the pump and the whole hydraulic system. There are situations in which, in principle, the cavitation could be avoided by detecting the condition of incipient cavitation, and changing slightly the working point of the whole system in order to move away from that condition. In the present paper two simple closed-loop control strategies are implemented, acting on the pump's rotational speed and fed by the measurements of a set of inertial sensors. In particular, the research is focused on a centrifugal pump normally employed in hydraulic systems. The pump operates in a dedicated test rig, where cavitation can be induced by acting on a reservoir's pressure. Three accelerometers are installed in the pump body along three orthogonal axes. An extensive set of experiments has been carried out at different flow rates and a number of signals' features both in the time domain and in the frequency domain have been considered as indicators of incipient cavitation. The amount of energy of the signal captured by the accelerometer in the component orthogonal to the flow direction, in the band from 10 to 12.8 kHz, demonstrated to be effective in detecting the incipient cavitation, by selecting a proper (condition-dependent) threshold. Therefore, two simple controllers have been designed: the first regulates the speed of the pump, to recover from cavitation, bringing the indicator back to the nominal value, while the second allows to reduce the pump's rotational speed when the cavitation detector indicates the incipient cavitation and restoring the nominal speed when possible. The latter approach is rather general, because the threshold-based detector can be substituted by any detector providing binary output. Experimental results are reported that demonstrate the effectiveness of the approach. … (more)
- Is Part Of:
- Energy procedia. Volume 148(2018)
- Journal:
- Energy procedia
- Issue:
- Volume 148(2018)
- Issue Display:
- Volume 148, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 148
- Issue:
- 2018
- Issue Sort Value:
- 2018-0148-2018-0000
- Page Start:
- 242
- Page End:
- 249
- Publication Date:
- 2018-08
- Subjects:
- Cavitation -- Centrifugal pump -- Closed-loop control
Power resources -- Congresses
Power resources -- Periodicals
Power resources
Conference proceedings
Periodicals
333.7905 - Journal URLs:
- http://www.sciencedirect.com/science/journal/18766102 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.egypro.2018.08.074 ↗
- Languages:
- English
- ISSNs:
- 1876-6102
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3747.729700
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11329.xml