Challenges in the measurement of plasma creatinine on the Roche cobas c702. (18th August 2018)
- Record Type:
- Journal Article
- Title:
- Challenges in the measurement of plasma creatinine on the Roche cobas c702. (18th August 2018)
- Main Title:
- Challenges in the measurement of plasma creatinine on the Roche cobas c702
- Authors:
- Jørn Erlandsen, Erland
Randers, Else - Abstract:
- Abstract: The aim of this study was to document the differences between two Roche creatinine measurement methods, the CREP2 test on the cobas c702 and the CREA PLUS test on the Modular P. Samples with creatinine isotope dilution mass spectrometry (IDMS) values were analyzed on both instruments. Method comparison using the remaining plasma samples was performed twice, using two different lot numbers of reagents and two different lot numbers of calibrators on both instruments. Medians and percentiles of the plasma creatinine values produced on the Modular P and cobas c702 from 2012 to 2017 were compared. The recovery of samples with IDMS creatinine values (SRM 967a level 1, SRM 967a level 2, serum X and five serum pools from Roche) was 101.7%–110.2% on the cobas c702 and 98.9%–102.6% on the Modular P. Comparison of the two methods showed that the slope was close to 1.0 using linear, Deming and Passing Bablok regressions, but all equations showed a negative intercept, indicating that the cobas c702 overestimates plasma creatinine in relation to the Modular P by 4–6 µmol/L. The median value for routine plasma creatinine lies between 74 and 77 µmol/L for the Modular P and 81 µmol/L for the cobas c702. After the cobas c702 was factorized in September 2016, the median plasma creatinine value decreased to 75 µmol/L. In conclusion, the CREP2 method on the cobas c702 overestimates creatinine by 4–6 μmol/L, which has a significant influence on the estimated glomerular filtration rateAbstract: The aim of this study was to document the differences between two Roche creatinine measurement methods, the CREP2 test on the cobas c702 and the CREA PLUS test on the Modular P. Samples with creatinine isotope dilution mass spectrometry (IDMS) values were analyzed on both instruments. Method comparison using the remaining plasma samples was performed twice, using two different lot numbers of reagents and two different lot numbers of calibrators on both instruments. Medians and percentiles of the plasma creatinine values produced on the Modular P and cobas c702 from 2012 to 2017 were compared. The recovery of samples with IDMS creatinine values (SRM 967a level 1, SRM 967a level 2, serum X and five serum pools from Roche) was 101.7%–110.2% on the cobas c702 and 98.9%–102.6% on the Modular P. Comparison of the two methods showed that the slope was close to 1.0 using linear, Deming and Passing Bablok regressions, but all equations showed a negative intercept, indicating that the cobas c702 overestimates plasma creatinine in relation to the Modular P by 4–6 µmol/L. The median value for routine plasma creatinine lies between 74 and 77 µmol/L for the Modular P and 81 µmol/L for the cobas c702. After the cobas c702 was factorized in September 2016, the median plasma creatinine value decreased to 75 µmol/L. In conclusion, the CREP2 method on the cobas c702 overestimates creatinine by 4–6 μmol/L, which has a significant influence on the estimated glomerular filtration rate (eGFR) in children. … (more)
- Is Part Of:
- Scandinavian journal of clinical & laboratory investigation. Volume 78:Number 6(2018)
- Journal:
- Scandinavian journal of clinical & laboratory investigation
- Issue:
- Volume 78:Number 6(2018)
- Issue Display:
- Volume 78, Issue 6 (2018)
- Year:
- 2018
- Volume:
- 78
- Issue:
- 6
- Issue Sort Value:
- 2018-0078-0006-0000
- Page Start:
- 490
- Page End:
- 495
- Publication Date:
- 2018-08-18
- Subjects:
- Analytical chemistry method -- creatinine -- glomerular filtration rate -- kidney function -- reference values
Clinical biochemistry -- Periodicals
Physiology, Pathological -- Periodicals
Physiology, Experimental -- Periodicals
Medicine -- Research -- Periodicals
Clinical medicine -- Periodicals
616.0072 - Journal URLs:
- http://informahealthcare.com/loi/clb ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/00365513.2018.1501090 ↗
- Languages:
- English
- ISSNs:
- 0036-5513
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8087.500000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11343.xml