Oxygen delivery using neonatal self‐inflating bags without reservoirs. Issue 2 (3rd January 2017)
- Record Type:
- Journal Article
- Title:
- Oxygen delivery using neonatal self‐inflating bags without reservoirs. Issue 2 (3rd January 2017)
- Main Title:
- Oxygen delivery using neonatal self‐inflating bags without reservoirs
- Authors:
- Sugiura, Takahiro
Urushibata, Rei
Komatsu, Kenji
Shioda, Tsutomu
Ota, Tatsuki
Sato, Megumi
Okubo, Yumiko
Fukuoka, Tetsuya
Hosono, Shigeharu
Tamura, Masanori - Abstract:
- Abstract: Background: Guidelines recommend avoiding excessive oxygen during neonatal resuscitation. Recent studies have suggested that oxygen titration can be achieved using a self‐inflating bag, but data on the effectiveness of resuscitators used in neonatal ventilation are scarce, The aim of this study was therefore to determine the amount of oxygen delivered using several brands of neonatal self‐inflating resuscitation bags without reservoirs under different conditions with regard to oxygen flow rate, ventilation rate (VR), peak inspiratory pressure (PIP) range, and test lung compliance. Methods: Oxygen concentration was measured under a variety of conditions. Combinations of oxygen flow rate (10, 5.0, 3.0 and 1.0 L/min), VR (40, 60 inflations/min), PIP range (20–25 cmH2 O, 35–40 cmH2 O), and test lung compliance (0.6, 1.0, 3.0, and 5.0 mL/cmH2 O) were examined using six kinds of self‐inflating bag. Results: Delivered oxygen concentration varied widely (30.1–96.7%) and had a significant positive correlation with gas flow rate in all of the bags. Delivered oxygen concentration was also negatively correlated with PIP in all of the bags and with VR in some of them. Test lung compliance did not affect delivered oxygen concentration. Conclusion: The use of neonatal resuscitation self‐inflating bags without reservoirs resulted in different delivered oxygen concentrations depending on gas flow rate, VR, PIP, and manufacturer, but not on lung compliance. This suggests thatAbstract: Background: Guidelines recommend avoiding excessive oxygen during neonatal resuscitation. Recent studies have suggested that oxygen titration can be achieved using a self‐inflating bag, but data on the effectiveness of resuscitators used in neonatal ventilation are scarce, The aim of this study was therefore to determine the amount of oxygen delivered using several brands of neonatal self‐inflating resuscitation bags without reservoirs under different conditions with regard to oxygen flow rate, ventilation rate (VR), peak inspiratory pressure (PIP) range, and test lung compliance. Methods: Oxygen concentration was measured under a variety of conditions. Combinations of oxygen flow rate (10, 5.0, 3.0 and 1.0 L/min), VR (40, 60 inflations/min), PIP range (20–25 cmH2 O, 35–40 cmH2 O), and test lung compliance (0.6, 1.0, 3.0, and 5.0 mL/cmH2 O) were examined using six kinds of self‐inflating bag. Results: Delivered oxygen concentration varied widely (30.1–96.7%) and had a significant positive correlation with gas flow rate in all of the bags. Delivered oxygen concentration was also negatively correlated with PIP in all of the bags and with VR in some of them. Test lung compliance did not affect delivered oxygen concentration. Conclusion: The use of neonatal resuscitation self‐inflating bags without reservoirs resulted in different delivered oxygen concentrations depending on gas flow rate, VR, PIP, and manufacturer, but not on lung compliance. This suggests that targeted oxygen concentrations could be delivered, even in lungs with decreased compliance, during resuscitation. … (more)
- Is Part Of:
- Pediatrics international. Volume 59:Issue 2(2017)
- Journal:
- Pediatrics international
- Issue:
- Volume 59:Issue 2(2017)
- Issue Display:
- Volume 59, Issue 2 (2017)
- Year:
- 2017
- Volume:
- 59
- Issue:
- 2
- Issue Sort Value:
- 2017-0059-0002-0000
- Page Start:
- 154
- Page End:
- 158
- Publication Date:
- 2017-01-03
- Subjects:
- lung compliance -- newborn -- oxygen -- positive pressure ventilation -- self‐inflating bag
Pediatrics -- Periodicals
618.92 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1442-200X/issues. Subscription to online journal required for access to full text. ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/ped.13184 ↗
- Languages:
- English
- ISSNs:
- 1328-8067
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6417.655800
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11344.xml