Electrode montage and gaze effects on ocular vestibular evoked myogenic potentials (oVEMPs). Issue 8 (August 2016)
- Record Type:
- Journal Article
- Title:
- Electrode montage and gaze effects on ocular vestibular evoked myogenic potentials (oVEMPs). Issue 8 (August 2016)
- Main Title:
- Electrode montage and gaze effects on ocular vestibular evoked myogenic potentials (oVEMPs)
- Authors:
- Govender, Sendhil
Cheng, Petrina Y.
Dennis, Danielle L.
Colebatch, James G. - Abstract:
- Highlights: oVEMPS were recorded using 5 electrodes around the orbital rim. Bipolar montages had better selectivity than a chin reference. A mid-lateral electrode location showed the most consistent latency and gaze effects. Abstract: Objectives: To investigate the properties of lateral electrode locations compared to the conventional ones and to bipolar compared to chin-referenced montages for recording ocular vestibular evoked myogenic potentials (oVEMPs). Methods: A total of 18 subjects were studied using 5 electrode locations around the eye, including the conventional location and more lateral ones (i.e. M, ML and L electrodes near the orbital margin, R1 and R2 electrodes below the two more medial ones). Unilateral air-conducted (AC) sound, bone-conducted (BC) impulses at the mastoid and BC vibration (500 Hz) at the forehead were used. These were applied while the subjects looked in neutral gaze and with 4 levels of increasing elevation. A subset of 10 subjects were also studied when looking downwards at 4 levels. Five bipolar montages were created offline by subtraction. Results: The M and ML electrodes had the largest responses but responses were seen for all 5 electrodes. The chin reference was associated with substantial pickup from the contralateral side (as judged using unilateral AC stimulation). The M-R1 (conventional) montage showed a significantly non-linear response to gaze angle, unlike the ML montages. The ML-R1 montage gave the largest responses. There wasHighlights: oVEMPS were recorded using 5 electrodes around the orbital rim. Bipolar montages had better selectivity than a chin reference. A mid-lateral electrode location showed the most consistent latency and gaze effects. Abstract: Objectives: To investigate the properties of lateral electrode locations compared to the conventional ones and to bipolar compared to chin-referenced montages for recording ocular vestibular evoked myogenic potentials (oVEMPs). Methods: A total of 18 subjects were studied using 5 electrode locations around the eye, including the conventional location and more lateral ones (i.e. M, ML and L electrodes near the orbital margin, R1 and R2 electrodes below the two more medial ones). Unilateral air-conducted (AC) sound, bone-conducted (BC) impulses at the mastoid and BC vibration (500 Hz) at the forehead were used. These were applied while the subjects looked in neutral gaze and with 4 levels of increasing elevation. A subset of 10 subjects were also studied when looking downwards at 4 levels. Five bipolar montages were created offline by subtraction. Results: The M and ML electrodes had the largest responses but responses were seen for all 5 electrodes. The chin reference was associated with substantial pickup from the contralateral side (as judged using unilateral AC stimulation). The M-R1 (conventional) montage showed a significantly non-linear response to gaze angle, unlike the ML montages. The ML-R1 montage gave the largest responses. There was a clear change in latency for the conventional montage with downgaze for the AC and BC impulsive stimuli. Conclusions: The ML active electrode has a more stable n1 latency, a larger and a more linear response to gaze angle than the conventional recording site, probably due to contamination by pickup of inferior rectus activity when using the conventional site. Significance: The ML location is a better site for the active pickup for recording oVEMPs if the main object of study is the inferior oblique muscle and particularly if subjects have difficulty with upgaze. … (more)
- Is Part Of:
- Clinical neurophysiology. Volume 127:Issue 8(2016:Aug.)
- Journal:
- Clinical neurophysiology
- Issue:
- Volume 127:Issue 8(2016:Aug.)
- Issue Display:
- Volume 127, Issue 8 (2016)
- Year:
- 2016
- Volume:
- 127
- Issue:
- 8
- Issue Sort Value:
- 2016-0127-0008-0000
- Page Start:
- 2846
- Page End:
- 2854
- Publication Date:
- 2016-08
- Subjects:
- oVEMP -- Gaze -- Electrode -- Montage
Neurophysiology -- Periodicals
Electroencephalography -- Periodicals
Electromyography -- Periodicals
Neurology -- Periodicals
612.8 - Journal URLs:
- http://www.sciencedirect.com/science/journal/13882457 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.clinph.2016.05.365 ↗
- Languages:
- English
- ISSNs:
- 1388-2457
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.310645
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11320.xml