Seismic performance of precast composite shear walls reinforced by concrete-filled steel tubes. (1st May 2018)
- Record Type:
- Journal Article
- Title:
- Seismic performance of precast composite shear walls reinforced by concrete-filled steel tubes. (1st May 2018)
- Main Title:
- Seismic performance of precast composite shear walls reinforced by concrete-filled steel tubes
- Authors:
- Wu, Liwei
Tian, Ying
Su, Youpo
Chen, Haibin - Abstract:
- Highlights: A new type of precast composite shear wall was proposed and experimentally studied. CFSTs completely replaced reinforcing bars in the boundary elements of RC walls. Sleeve-mortar connections with proposed detailing can reliably transfer loads. The CFST walls presented better strength and deformation capacity than RC walls. Abstract: A type of precast slender composite shear wall was proposed and experimentally studied. In this new precast structural wall system, concrete-filled steel tubes (CFSTs) were used to entirely replace the longitudinal reinforcement in the boundary elements of conventional reinforced concrete (RC) shear walls. At joints, the CFSTs and wall web reinforcement were connected by sleeves filled with high-strength mortar. To examine the seismic performance of the proposed system, seven 1/3-scale specimens were built and tested under quasi-static and dynamic cyclic lateral loading with a top displacement rate up to 20 mm/s. Major test variables included axial force ratio ranging from 0.075 to 0.19 and loading rate. This paper reports the damage pattern, hysteretic load-deformation response, energy dissipation capacity, and connection performance of the test specimens. Under the considered axial force levels and loading rates, lateral loads were successfully resisted at the joints and the response of all specimens was dominated by flexure. The use of CFSTs increased lateral strength and deformation capacity. The highest axial force ratio causedHighlights: A new type of precast composite shear wall was proposed and experimentally studied. CFSTs completely replaced reinforcing bars in the boundary elements of RC walls. Sleeve-mortar connections with proposed detailing can reliably transfer loads. The CFST walls presented better strength and deformation capacity than RC walls. Abstract: A type of precast slender composite shear wall was proposed and experimentally studied. In this new precast structural wall system, concrete-filled steel tubes (CFSTs) were used to entirely replace the longitudinal reinforcement in the boundary elements of conventional reinforced concrete (RC) shear walls. At joints, the CFSTs and wall web reinforcement were connected by sleeves filled with high-strength mortar. To examine the seismic performance of the proposed system, seven 1/3-scale specimens were built and tested under quasi-static and dynamic cyclic lateral loading with a top displacement rate up to 20 mm/s. Major test variables included axial force ratio ranging from 0.075 to 0.19 and loading rate. This paper reports the damage pattern, hysteretic load-deformation response, energy dissipation capacity, and connection performance of the test specimens. Under the considered axial force levels and loading rates, lateral loads were successfully resisted at the joints and the response of all specimens was dominated by flexure. The use of CFSTs increased lateral strength and deformation capacity. The highest axial force ratio caused drift capacity to be reduced from 2.5% to 2.0%. Although loading rate nearly had no influence on either lateral stiffness or strength, it reduced energy dissipation capacity. Finally, the effectiveness of proposed detailing of sleeve-mortar connections in load transfer was validated by the similar hysteric response, joint opening, and wall sliding between monolithic and precast CFST wall specimens. … (more)
- Is Part Of:
- Engineering structures. Volume 162(2018)
- Journal:
- Engineering structures
- Issue:
- Volume 162(2018)
- Issue Display:
- Volume 162, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 162
- Issue:
- 2018
- Issue Sort Value:
- 2018-0162-2018-0000
- Page Start:
- 72
- Page End:
- 83
- Publication Date:
- 2018-05-01
- Subjects:
- Concrete-filled steel tube -- Precast wall -- Composite wall -- Axial force ratio -- Loading rate -- Seismic behavior
Structural engineering -- Periodicals
Structural analysis (Engineering) -- Periodicals
Construction, Technique de la -- Périodiques
Génie parasismique -- Périodiques
Pression du vent -- Périodiques
Earthquake engineering
Structural engineering
Wind-pressure
Periodicals
624.105 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01410296 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.engstruct.2018.01.069 ↗
- Languages:
- English
- ISSNs:
- 0141-0296
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3770.032000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11321.xml