Numerical investigations on the axial capacity of back-to-back gapped built-up cold-formed stainless steel channels. Issue 10 (July 2019)
- Record Type:
- Journal Article
- Title:
- Numerical investigations on the axial capacity of back-to-back gapped built-up cold-formed stainless steel channels. Issue 10 (July 2019)
- Main Title:
- Numerical investigations on the axial capacity of back-to-back gapped built-up cold-formed stainless steel channels
- Authors:
- Roy, Krishanu
Lau, Hieng Ho
Lim, James BP - Abstract:
- Cold-formed stainless steel is becoming popular as a structural member with its increased corrosion resistance and durability when compared with carbon steel. Examples of cold-formed steel structures include trusses, wall frames and portal frames. In cases where increased axial capacity is required, it is becoming increasingly popular to use back-to-back gapped built-up channels, instead of just back-to-back sections. In such an arrangement, however, the beneficial effect of the gap between the back-to-back cold-formed steel channels is ignored by the current design guidelines (American Iron and Steel Institute and the Australian and New Zealand Standard and Eurocode (EN 1993-1-3)) for both cold-formed carbon as well as cold-formed stainless steel. We have considered this issue both experimentally and numerically through finite element analysis for cold-formed carbon steel; from the results of this work, design recommendations were proposed. These results, however, are not applicable to cold-formed stainless steel. This issue is addressed numerically herein. Using the finite element model previously developed for cold-formed carbon steel, an extensive parametric study, comprising 589 models is described. Three different grades of stainless steel, that is, ferritic EN1.4003, austenitic EN1.4404 and duplex EN1.4462 have been considered. The effect of the gap between the two back-to-back channels, slenderness, link-channel spacing and different cross-sectional geometries areCold-formed stainless steel is becoming popular as a structural member with its increased corrosion resistance and durability when compared with carbon steel. Examples of cold-formed steel structures include trusses, wall frames and portal frames. In cases where increased axial capacity is required, it is becoming increasingly popular to use back-to-back gapped built-up channels, instead of just back-to-back sections. In such an arrangement, however, the beneficial effect of the gap between the back-to-back cold-formed steel channels is ignored by the current design guidelines (American Iron and Steel Institute and the Australian and New Zealand Standard and Eurocode (EN 1993-1-3)) for both cold-formed carbon as well as cold-formed stainless steel. We have considered this issue both experimentally and numerically through finite element analysis for cold-formed carbon steel; from the results of this work, design recommendations were proposed. These results, however, are not applicable to cold-formed stainless steel. This issue is addressed numerically herein. Using the finite element model previously developed for cold-formed carbon steel, an extensive parametric study, comprising 589 models is described. Three different grades of stainless steel, that is, ferritic EN1.4003, austenitic EN1.4404 and duplex EN1.4462 have been considered. The effect of the gap between the two back-to-back channels, slenderness, link-channel spacing and different cross-sectional geometries are investigated. The finite element results were then used to verify the accuracy of current design guidelines by the American Iron and Steel Institute and the Australian and New Zealand Standard and Eurocode (EN 1993-1-3). It was found that the American Iron and Steel Institute and the Australian and New Zealand Standard and Eurocode (EN 1993-1-3) can be over conservative by as much as 68% when calculating the axial capacity of such built-up gapped stainless steel columns. Therefore, a design recommendation is proposed to modify the non-dimensional slenderness so to consider the gap. This leads to the American Iron and Steel Institute and the Australian and New Zealand Standard and Eurocode (EN 1993-1-3) being within 7% conservative to the finite element results. … (more)
- Is Part Of:
- Advances in structural engineering. Volume 22:Issue 10(2019)
- Journal:
- Advances in structural engineering
- Issue:
- Volume 22:Issue 10(2019)
- Issue Display:
- Volume 22, Issue 10 (2019)
- Year:
- 2019
- Volume:
- 22
- Issue:
- 10
- Issue Sort Value:
- 2019-0022-0010-0000
- Page Start:
- 2289
- Page End:
- 2310
- Publication Date:
- 2019-07
- Subjects:
- axial strength -- buckling -- built-up-sections -- cold-formed stainless steel -- compression member -- finite element analysis -- gap
Structural engineering -- Periodicals
Construction, Technique de la
Structural engineering
Periodicals
624.1 - Journal URLs:
- http://ase.sagepub.com/ ↗
http://multi-science.metapress.com/content/121491 ↗
http://www.ingenta.com/journals/browse/mscp/ase ↗
http://www.multi-science.co.uk/ ↗ - DOI:
- 10.1177/1369433219837390 ↗
- Languages:
- English
- ISSNs:
- 1369-4332
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11323.xml