Fluoroscopic balloon diameter measurement at different pressures during Eustachian balloon dilation. (12th September 2018)
- Record Type:
- Journal Article
- Title:
- Fluoroscopic balloon diameter measurement at different pressures during Eustachian balloon dilation. (12th September 2018)
- Main Title:
- Fluoroscopic balloon diameter measurement at different pressures during Eustachian balloon dilation
- Authors:
- Kang, Byung Chul
Kang, Woo Seok
Park, Jun Woo
Park, Jung‐Hoon
Kim, Kun Yung
Song, Ho‐Young
Park, Hong Ju - Abstract:
- Abstract : Objectives: To measure the diameter of inflated balloons at different pressures during Eustachian tube (ET) balloon dilation under fluoroscopic guidance. Design: Prospective cohort study. Setting: Tertiary academic referral centre. Participants: Eighteen patients who underwent ET balloon dilation with use of a balloon catheter, 20 mm long and 6 mm in diameter, under combined endoscopic and fluoroscopic guidance. Main outcome measures: Degrees of inflation at three different portions (proximal, middle and distal) of the balloon at controlled pressures (3, 5, 8 and 10 atmospheres [atm]) and at the maximum pressure manually applied. Results: The mean proximal, middle and distal diameters of the inflated balloons were 5.3 ± 0.4 mm, 5.3 ± 0.4 mm and 4.9 ± 0.5 mm at 10 atm. The distal diameters were significantly smaller than middle and proximal diameters at all the pressures ( P < 0.01). When compared to the distal diameter (100%, 4.9 ± 0.5 mm) at 10 atm, the distal diameters were 73% (3.6 ± 0.6 mm) at 3 atm, 88% (4.3 ± 0.5 mm) at 5 atm and 96% (4.7 ± 0.4 mm) at 8 atm. The distal diameter (4.1 ± 0.3 mm) at the maximum pressure manually applied was in between those at 3 and 5 atm. Conclusions: The distal diameter of the balloon increased significantly as a function of the pressure and most (88%) inflation occurred at a low pressure of 5 atm, which was sufficient to inflate the distal diameter of the balloon more than 3 mm. The manual pressurisation could inflate aAbstract : Objectives: To measure the diameter of inflated balloons at different pressures during Eustachian tube (ET) balloon dilation under fluoroscopic guidance. Design: Prospective cohort study. Setting: Tertiary academic referral centre. Participants: Eighteen patients who underwent ET balloon dilation with use of a balloon catheter, 20 mm long and 6 mm in diameter, under combined endoscopic and fluoroscopic guidance. Main outcome measures: Degrees of inflation at three different portions (proximal, middle and distal) of the balloon at controlled pressures (3, 5, 8 and 10 atmospheres [atm]) and at the maximum pressure manually applied. Results: The mean proximal, middle and distal diameters of the inflated balloons were 5.3 ± 0.4 mm, 5.3 ± 0.4 mm and 4.9 ± 0.5 mm at 10 atm. The distal diameters were significantly smaller than middle and proximal diameters at all the pressures ( P < 0.01). When compared to the distal diameter (100%, 4.9 ± 0.5 mm) at 10 atm, the distal diameters were 73% (3.6 ± 0.6 mm) at 3 atm, 88% (4.3 ± 0.5 mm) at 5 atm and 96% (4.7 ± 0.4 mm) at 8 atm. The distal diameter (4.1 ± 0.3 mm) at the maximum pressure manually applied was in between those at 3 and 5 atm. Conclusions: The distal diameter of the balloon increased significantly as a function of the pressure and most (88%) inflation occurred at a low pressure of 5 atm, which was sufficient to inflate the distal diameter of the balloon more than 3 mm. The manual pressurisation could inflate a balloon by as much as could be expected, at between 3 and 5 atm. … (more)
- Is Part Of:
- Clinical otolaryngology. Volume 43:Number 6(2018)
- Journal:
- Clinical otolaryngology
- Issue:
- Volume 43:Number 6(2018)
- Issue Display:
- Volume 43, Issue 6 (2018)
- Year:
- 2018
- Volume:
- 43
- Issue:
- 6
- Issue Sort Value:
- 2018-0043-0006-0000
- Page Start:
- 1573
- Page End:
- 1577
- Publication Date:
- 2018-09-12
- Subjects:
- balloon catheter -- dilation -- Eustachian tube -- otitis media -- pressure
Otolaryngology -- Periodicals
617.51005 - Journal URLs:
- http://www.blackwell-synergy.com/loi/coa ↗
http://onlinelibrary.wiley.com/ ↗
http://www.blackwellpublishing.com/journal.asp?ref=0307-7772&site=1 ↗ - DOI:
- 10.1111/coa.13218 ↗
- Languages:
- English
- ISSNs:
- 1749-4478
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.324050
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11308.xml