Evaluation of quantitative 123I and 131I SPECT with Monte Carlo-based down-scatter compensation. Issue 12 (December 2018)
- Record Type:
- Journal Article
- Title:
- Evaluation of quantitative 123I and 131I SPECT with Monte Carlo-based down-scatter compensation. Issue 12 (December 2018)
- Main Title:
- Evaluation of quantitative 123I and 131I SPECT with Monte Carlo-based down-scatter compensation
- Authors:
- Kangasmaa, Tuija S.
Constable, Chris
Sohlberg, Antti O. - Abstract:
- Abstract : Objective: Quantitative 123 I and 131 I single-photon emission computed tomography (SPECT) is hampered by down-scatter from the high-energy peaks. This paper presents a down-scatter compensation method, where down-scatter generated in the patient and gamma camera collimator and detector is modelled using Monte Carlo simulation in the ordered subsets expectation maximization SPECT reconstruction algorithm. Materials and methods: The new down-scatter compensation method was compared with conventional triple energy window (TEW) scatter compensation and Gaussian convolution-based forced detection Monte Carlo methods. The comparison was made with the NEMA-IEC phantom using six spherical inserts (diameters from 10 to 37 mm) and a lung compartment. The phantom was filled with 123 I and 131 I solutions to known sphere-to-background concentration ratios. Spherical volumes of interest with the same diameter as the inserts were drawn on the images, and recovery coefficients for the spheres were calculated in addition to lung-to-background ratio. Results: The new down-scatter compensation method provided higher recovery coefficients than the TEW scatter compensation or Gaussian convolution-based forced detection Monte Carlo algorithm for both isotopes. Background activity concentration could be accurately estimated with the new down-scatter compensation method and with the TEW scatter compensation, whereas activity concentration of the spheres was severely underestimated evenAbstract : Objective: Quantitative 123 I and 131 I single-photon emission computed tomography (SPECT) is hampered by down-scatter from the high-energy peaks. This paper presents a down-scatter compensation method, where down-scatter generated in the patient and gamma camera collimator and detector is modelled using Monte Carlo simulation in the ordered subsets expectation maximization SPECT reconstruction algorithm. Materials and methods: The new down-scatter compensation method was compared with conventional triple energy window (TEW) scatter compensation and Gaussian convolution-based forced detection Monte Carlo methods. The comparison was made with the NEMA-IEC phantom using six spherical inserts (diameters from 10 to 37 mm) and a lung compartment. The phantom was filled with 123 I and 131 I solutions to known sphere-to-background concentration ratios. Spherical volumes of interest with the same diameter as the inserts were drawn on the images, and recovery coefficients for the spheres were calculated in addition to lung-to-background ratio. Results: The new down-scatter compensation method provided higher recovery coefficients than the TEW scatter compensation or Gaussian convolution-based forced detection Monte Carlo algorithm for both isotopes. Background activity concentration could be accurately estimated with the new down-scatter compensation method and with the TEW scatter compensation, whereas activity concentration of the spheres was severely underestimated even with the new method. Conclusion: Down-scatter compensation with Monte Carlo-simulation effectively reduces down-scatter effects in 123 I and 131 I SPECT imaging. … (more)
- Is Part Of:
- Nuclear medicine communications. Volume 39:Issue 12(2018:Dec.)
- Journal:
- Nuclear medicine communications
- Issue:
- Volume 39:Issue 12(2018:Dec.)
- Issue Display:
- Volume 39, Issue 12 (2018)
- Year:
- 2018
- Volume:
- 39
- Issue:
- 12
- Issue Sort Value:
- 2018-0039-0012-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-12
- Subjects:
- 123I -- 131I -- Monte Carlo -- quantitative SPECT -- scatter compensation
Nuclear medicine -- Periodicals
616.07575 - Journal URLs:
- http://journals.lww.com/nuclearmedicinecomm/pages/default.aspx ↗
http://journals.lww.com/pages/default.aspx ↗
http://www.lww.com/Product/0143-3636 ↗ - DOI:
- 10.1097/MNM.0000000000000920 ↗
- Languages:
- English
- ISSNs:
- 0143-3636
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6180.923000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11289.xml