Mean mid-arm circumference and blood pressure cuff sizes for US children, adolescents and adults: National Health and Nutrition Examination Survey, 2011–2016. Issue 6 (December 2018)
- Record Type:
- Journal Article
- Title:
- Mean mid-arm circumference and blood pressure cuff sizes for US children, adolescents and adults: National Health and Nutrition Examination Survey, 2011–2016. Issue 6 (December 2018)
- Main Title:
- Mean mid-arm circumference and blood pressure cuff sizes for US children, adolescents and adults
- Authors:
- Ostchega, Yechiam
Hughes, Jeffery P.
Nwankwo, Tatiana
Zhang, Guangyu - Abstract:
- Abstract : Background: Measuring blood pressure (BP) requires an appropriate BP cuff size given measured mid-arm circumference (mid-AC). Objective: To provide mid-AC means and percentiles for US population aged more than 3 years and examine the frequency distribution of mid-AC cuffed by Baum and Welch Allyn cuff systems. Patients and methods: The 2011–2016 National Health and Nutrition Examination Survey, a cross-sectional survey, was used to estimate mean mid-AC ( n =24 723). Results: Mean mid-AC did not differ from 2011 to 2016 (31.0 vs. 31.3 cm, P >0.05). During 2011–2016, mean mid-AC was greater for males than females (32.0 vs. 30.4 cm, P <0.001) and was largest among adults 40–49 years (34.0 cm). Non-Hispanic Black persons had the largest mean mid-AC (32.0 cm) and non-Hispanic Asian persons the smallest (28.4 cm). Increased BMI was associated with increased mean mid-AC for those 3–19 years (normal, 22.0 cm and obese, 31.5 cm, P <0.001) and more than 20 years (normal, 28.2 cm and obese, 37.8 cm, P <0.001). Among those aged 8–17 years, high BP status was associated with a larger mean mid-AC (normotensive 26.1 cm vs. high BP 28.2 cm, P =0.001). Among adults aged 18 years and older, hypertension status was associated with a larger mean mid-AC (normotensive 32.4 cm vs. hypertensive 34.2 cm, P <0.001). Among those aged 12–19 years, 13.0% required a Baum large cuff (35–46.9 cm mid-AC) and 21.7% required a Welch Allyn large cuff (32–39.9 cm mid-AC). Among those aged more thanAbstract : Background: Measuring blood pressure (BP) requires an appropriate BP cuff size given measured mid-arm circumference (mid-AC). Objective: To provide mid-AC means and percentiles for US population aged more than 3 years and examine the frequency distribution of mid-AC cuffed by Baum and Welch Allyn cuff systems. Patients and methods: The 2011–2016 National Health and Nutrition Examination Survey, a cross-sectional survey, was used to estimate mean mid-AC ( n =24 723). Results: Mean mid-AC did not differ from 2011 to 2016 (31.0 vs. 31.3 cm, P >0.05). During 2011–2016, mean mid-AC was greater for males than females (32.0 vs. 30.4 cm, P <0.001) and was largest among adults 40–49 years (34.0 cm). Non-Hispanic Black persons had the largest mean mid-AC (32.0 cm) and non-Hispanic Asian persons the smallest (28.4 cm). Increased BMI was associated with increased mean mid-AC for those 3–19 years (normal, 22.0 cm and obese, 31.5 cm, P <0.001) and more than 20 years (normal, 28.2 cm and obese, 37.8 cm, P <0.001). Among those aged 8–17 years, high BP status was associated with a larger mean mid-AC (normotensive 26.1 cm vs. high BP 28.2 cm, P =0.001). Among adults aged 18 years and older, hypertension status was associated with a larger mean mid-AC (normotensive 32.4 cm vs. hypertensive 34.2 cm, P <0.001). Among those aged 12–19 years, 13.0% required a Baum large cuff (35–46.9 cm mid-AC) and 21.7% required a Welch Allyn large cuff (32–39.9 cm mid-AC). Among those aged more than 20 years, 33.2% required a Baum large cuff, 48.2% required a Welch Allyn large cuff, 1.3% required a Baum extra-large cuff (44–66 cm mid-AC), and 9.5% required a Welch Allyn extra-large cuff (40–55 cm mid-AC). Conclusion: Currently, BP is obtained in clinic, pharmacy, home, and ambulatory setting using single or multiple cuffs. National Health and Nutrition Examination Survey mid-AC data should be considered for accurate cuffing avoiding cuff hypertension or hypotension. … (more)
- Is Part Of:
- Blood pressure monitoring. Volume 23:Issue 6(2018)
- Journal:
- Blood pressure monitoring
- Issue:
- Volume 23:Issue 6(2018)
- Issue Display:
- Volume 23, Issue 6 (2018)
- Year:
- 2018
- Volume:
- 23
- Issue:
- 6
- Issue Sort Value:
- 2018-0023-0006-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-12
- Subjects:
- blood pressure cuff sizes -- mid-arm circumference -- National Health and Nutrition Examination Survey
Blood pressure -- Measurement -- Periodicals
Blood Pressure Determination -- Periodicals
Blood Pressure Monitoring, Ambulatory -- Periodicals
Blood Pressure Monitors -- Periodicals
Hypertension -- Periodicals
612.140287 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00126097-000000000-00000&NEWS=N ↗
http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00126097-000000000-00000 ↗
http://www.bpmonitoring.com/ ↗
http://journals.lww.com/pages/default.aspx ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1097/MBP.0000000000000349 ↗
- Languages:
- English
- ISSNs:
- 1359-5237
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2113.035500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11311.xml