Molecular Bioburden of the Lens Storage Case for Contact Lens–Related Keratitis. Issue 12 (December 2018)
- Record Type:
- Journal Article
- Title:
- Molecular Bioburden of the Lens Storage Case for Contact Lens–Related Keratitis. Issue 12 (December 2018)
- Main Title:
- Molecular Bioburden of the Lens Storage Case for Contact Lens–Related Keratitis
- Authors:
- Hsiao, Yu-Ting
Fang, Po-Chiung
Chen, Jiunn-Liang
Hsu, Shiuh-Liang
Chao, Tsai-Ling
Yu, Hun-Ju
Lai, Yu-Hsuan
Huang, Yu-Ting
Kuo, Ming-Tse - Abstract:
- Abstract : Purpose: To elucidate the bioburden of a lens care system in patients with contact lens (CL)-related keratitis. Methods: In this prospective case–control study, the CL storage case was used as the target of bioburden assessment. Participants were CL wearers with (n = 26) or without (n = 24) keratitis in southern Taiwan. The case fluid sample was consecutively collected and assessed using a dot hybridization assay (DHA) for bioburden assessment. The DHA was composed of 3 universal bacterial probes for detecting all bacteria, genus-specific probes for Pseudomonas and Acinetobacter, and 1 probe for Acanthamoeba . The receiver operating characteristic curve was used to analyze the differentiating performance of a probe. Results: The storage case bioburden was significantly higher in those with CL-related keratitis than in control subjects; patients with CL-related keratitis had stronger standardized signals in all universal bacterial probes. Moreover, in the cases of these patients, the bioburden was significantly heavier in confirmed infectious keratitis than in presumed noninfectious keratitis. Receiver operating characteristic analysis showed that stronger signals in all 3 universal bacterial probes and the Pseudomonas probe might suggest that the wearers have infectious keratitis. Only the storage case of the Acanthamoeba keratitis case showed positive detection by the Acanthamoeba probe. Conclusions: A heavier bioburden in the lens storage case was associatedAbstract : Purpose: To elucidate the bioburden of a lens care system in patients with contact lens (CL)-related keratitis. Methods: In this prospective case–control study, the CL storage case was used as the target of bioburden assessment. Participants were CL wearers with (n = 26) or without (n = 24) keratitis in southern Taiwan. The case fluid sample was consecutively collected and assessed using a dot hybridization assay (DHA) for bioburden assessment. The DHA was composed of 3 universal bacterial probes for detecting all bacteria, genus-specific probes for Pseudomonas and Acinetobacter, and 1 probe for Acanthamoeba . The receiver operating characteristic curve was used to analyze the differentiating performance of a probe. Results: The storage case bioburden was significantly higher in those with CL-related keratitis than in control subjects; patients with CL-related keratitis had stronger standardized signals in all universal bacterial probes. Moreover, in the cases of these patients, the bioburden was significantly heavier in confirmed infectious keratitis than in presumed noninfectious keratitis. Receiver operating characteristic analysis showed that stronger signals in all 3 universal bacterial probes and the Pseudomonas probe might suggest that the wearers have infectious keratitis. Only the storage case of the Acanthamoeba keratitis case showed positive detection by the Acanthamoeba probe. Conclusions: A heavier bioburden in the lens storage case was associated with a higher risk of CL-related keratitis and infectious keratitis. Inappropriate maintenance of the CL will lead to microbial contamination and transfer the pathogen onto the ocular surface causing keratitis accordingly. The DHA assessment for the lens storage case might provide an alternative way to differentiate infectious from noninfectious CL-related keratitis. … (more)
- Is Part Of:
- Cornea. Volume 37:Issue 12(2018)
- Journal:
- Cornea
- Issue:
- Volume 37:Issue 12(2018)
- Issue Display:
- Volume 37, Issue 12 (2018)
- Year:
- 2018
- Volume:
- 37
- Issue:
- 12
- Issue Sort Value:
- 2018-0037-0012-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-12
- Subjects:
- contact lens -- keratitis -- lens care system -- dot hybridization assay -- bioburden
Cornea -- Periodicals
Cornea -- Periodicals
Cornée -- Périodiques
617.719 - Journal URLs:
- http://journals.lww.com/corneajrnl/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/ICO.0000000000001699 ↗
- Languages:
- English
- ISSNs:
- 0277-3740
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3470.927500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11297.xml