Impact of underlying plaque type on strut coverage in the early phase after drug-eluting stent implantation. Issue 8 (December 2018)
- Record Type:
- Journal Article
- Title:
- Impact of underlying plaque type on strut coverage in the early phase after drug-eluting stent implantation. Issue 8 (December 2018)
- Main Title:
- Impact of underlying plaque type on strut coverage in the early phase after drug-eluting stent implantation
- Authors:
- Kakizaki, Ryota
Minami, Yoshiyasu
Hashikata, Takehiro
Nemoto, Teruyoshi
Hashimoto, Takuya
Fujiyoshi, Kazuhiro
Meguro, Kentaro
Shimohama, Takao
Tojo, Taiki
Ako, Junya - Abstract:
- Abstract : Background: The aim of this study was to investigate whether the underlying plaque type affects the neointimal coverage after drug-eluting stent implantation. Methods: A total of 1793 struts in 22 zotarolimus-eluting stents were assessed using optical coherence tomography imaging within 3 months of implantation. Neointimal coverage was evaluated within 5 mm from each stent edge on cross-sectional optical coherence tomography images at every 1-mm interval. The percentage of struts covered by neointima was compared among the normal segment group, the fibrous plaque group, and the lipid plaque group on the basis of the underlying plaque type. Results: The percentage of covered strut was significantly lower in the normal segment group than in the fibrous plaque group (35.9±30.2 vs. 57.1±31.0%, P <0.05) and the lipid plaque group (vs. 64.7±23.5%, P <0.01). The neointima was significantly thinner in the normal segment group than in the lipid plaque group (19.0±22.3 vs. 32.0±18.8 μm, P <0.01). The percentage of struts on the normal segment was significantly higher in cross-sections with a ratio of uncovered to total struts per section more than 0.3 than in cross-sections with a ratio up to 0.3 (32.4±31.7 vs. 19.5±33.8%, P <0.01). Conclusion: Struts on the normal segment were less covered and had thinner neointima than struts on the lipid plaque at the stent edge within 3 months after zotarolimus-eluting stent implantation. Caution should be exercised when implantingAbstract : Background: The aim of this study was to investigate whether the underlying plaque type affects the neointimal coverage after drug-eluting stent implantation. Methods: A total of 1793 struts in 22 zotarolimus-eluting stents were assessed using optical coherence tomography imaging within 3 months of implantation. Neointimal coverage was evaluated within 5 mm from each stent edge on cross-sectional optical coherence tomography images at every 1-mm interval. The percentage of struts covered by neointima was compared among the normal segment group, the fibrous plaque group, and the lipid plaque group on the basis of the underlying plaque type. Results: The percentage of covered strut was significantly lower in the normal segment group than in the fibrous plaque group (35.9±30.2 vs. 57.1±31.0%, P <0.05) and the lipid plaque group (vs. 64.7±23.5%, P <0.01). The neointima was significantly thinner in the normal segment group than in the lipid plaque group (19.0±22.3 vs. 32.0±18.8 μm, P <0.01). The percentage of struts on the normal segment was significantly higher in cross-sections with a ratio of uncovered to total struts per section more than 0.3 than in cross-sections with a ratio up to 0.3 (32.4±31.7 vs. 19.5±33.8%, P <0.01). Conclusion: Struts on the normal segment were less covered and had thinner neointima than struts on the lipid plaque at the stent edge within 3 months after zotarolimus-eluting stent implantation. Caution should be exercised when implanting longer drug-eluting stents to achieve uniform strut coverage in the early phase. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Coronary artery disease. Volume 29:Issue 8(2018:Dec.)
- Journal:
- Coronary artery disease
- Issue:
- Volume 29:Issue 8(2018:Dec.)
- Issue Display:
- Volume 29, Issue 8 (2018)
- Year:
- 2018
- Volume:
- 29
- Issue:
- 8
- Issue Sort Value:
- 2018-0029-0008-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-12
- Subjects:
- coronary plaque -- drug-eluting stent -- neointimal hyperplasia -- optical coherence tomography -- strut coverage
Coronary heart disease -- Periodicals
Coronary Disease -- Indexes
Coronary Disease -- Periodicals
616.123005 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=00019501-000000000-00000 ↗
http://www.coronary-artery.com/ ↗
http://journals.lww.com/pages/default.aspx ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1097/MCA.0000000000000654 ↗
- Languages:
- English
- ISSNs:
- 0954-6928
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3472.049000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11298.xml