Glaucoma Gel Implant Learning Curve in a Teaching Tertiary Hospital. Issue 1 (January 2019)
- Record Type:
- Journal Article
- Title:
- Glaucoma Gel Implant Learning Curve in a Teaching Tertiary Hospital. Issue 1 (January 2019)
- Main Title:
- Glaucoma Gel Implant Learning Curve in a Teaching Tertiary Hospital
- Authors:
- Marques, Raquel Esteves
Ferreira, Nuno Pinto
Sousa, David Cordeiro
Pinto, Joana
Barata, André
Sens, Paula
Abegão Pinto, Luís - Abstract:
- Abstract : Purpose: The XEN gel stent is a minimally invasive surgical device aimed at creating a subconjunctival drainage of aqueous humor, thereby reducing intraocular pressure (IOP). Being a novel device, doubts remain with regard to the efficacy and safety of its implantation in the early stage of new users. This paper illustrates the XEN implantation learning curve, assessed through several surgeons of different expertise. Methods: This was a retrospective study on the first 6 XEN implants performed by each of the 10 certified ophthalmic surgeons. Simultaneous cataract surgery was allowed (phaco-XEN). Primary outcomes were as follows: surgical time; intraoperative and postoperative surgical complications. Secondary outcomes were as follows: IOP; the number of topical drugs in use; the need for needling procedures. Outcome data were collected preoperatively and at postoperative days 1, 7, 15, 30, 60, and 90. Statistical analysis was performed with STATA 14.1 and SPSS. Results: Sixty patients were included (56.7% female patients). Mean age was 73 years (45 to 89). Mean preoperative IOP was 23.8±8.95 mm Hg. From the included patients, 29 (48.3%) were submitted to simple XEN implant and 31 (51.7%) to phaco-XEN. In both groups, mean surgical time decreased by 9 minutes throughout the 6-implant learning curve. Final IOP was 15±7.27 mm Hg in the stent group (−43% than baseline), and 14.92±3.32 mm Hg in the phaco-XEN group (−16% than baseline). On average, patients decreased 2Abstract : Purpose: The XEN gel stent is a minimally invasive surgical device aimed at creating a subconjunctival drainage of aqueous humor, thereby reducing intraocular pressure (IOP). Being a novel device, doubts remain with regard to the efficacy and safety of its implantation in the early stage of new users. This paper illustrates the XEN implantation learning curve, assessed through several surgeons of different expertise. Methods: This was a retrospective study on the first 6 XEN implants performed by each of the 10 certified ophthalmic surgeons. Simultaneous cataract surgery was allowed (phaco-XEN). Primary outcomes were as follows: surgical time; intraoperative and postoperative surgical complications. Secondary outcomes were as follows: IOP; the number of topical drugs in use; the need for needling procedures. Outcome data were collected preoperatively and at postoperative days 1, 7, 15, 30, 60, and 90. Statistical analysis was performed with STATA 14.1 and SPSS. Results: Sixty patients were included (56.7% female patients). Mean age was 73 years (45 to 89). Mean preoperative IOP was 23.8±8.95 mm Hg. From the included patients, 29 (48.3%) were submitted to simple XEN implant and 31 (51.7%) to phaco-XEN. In both groups, mean surgical time decreased by 9 minutes throughout the 6-implant learning curve. Final IOP was 15±7.27 mm Hg in the stent group (−43% than baseline), and 14.92±3.32 mm Hg in the phaco-XEN group (−16% than baseline). On average, patients decreased 2 topical IOP-lowering drugs. Needling procedures were performed in 17 patients (28.3%). Conclusions: XEN gel stent was associated with a fast learning curve, by both experienced surgeons and novice residents. By the sixth implant, both groups had considerably decreased mean surgical time and complication rates. … (more)
- Is Part Of:
- Journal of glaucoma. Volume 28:Issue 1(2019)
- Journal:
- Journal of glaucoma
- Issue:
- Volume 28:Issue 1(2019)
- Issue Display:
- Volume 28, Issue 1 (2019)
- Year:
- 2019
- Volume:
- 28
- Issue:
- 1
- Issue Sort Value:
- 2019-0028-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-01
- Subjects:
- glaucoma -- ocular hypertension -- XEN -- minimally invasive glaucoma surgery -- MIGS
Glaucoma -- Periodicals
617.741005 - Journal URLs:
- http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00061198-000000000-00000 ↗
http://www.glaucomajournal.com ↗
http://journals.lww.com/glaucomajournal/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/IJG.0000000000001107 ↗
- Languages:
- English
- ISSNs:
- 1057-0829
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4996.230000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11292.xml