Long-Term Results of Femtosecond Laser–Enabled Keratoplasty With Zig-Zag Trephination. Issue 1 (January 2019)
- Record Type:
- Journal Article
- Title:
- Long-Term Results of Femtosecond Laser–Enabled Keratoplasty With Zig-Zag Trephination. Issue 1 (January 2019)
- Main Title:
- Long-Term Results of Femtosecond Laser–Enabled Keratoplasty With Zig-Zag Trephination
- Authors:
- Wade, Matthew
Muniz Castro, Hannah
Garg, Sumit
Kedhar, Sanjay
Aggarwal, Sahil
Shumway, Caleb
Farid, Marjan - Abstract:
- Abstract : Purpose: To report long-term visual and astigmatism outcomes in cases of zig-zag femtosecond laser–enabled penetrating keratoplasty (FLEK). Methods: Retrospective review. Three hundred thirty-five eyes of 287 patients underwent (FLEK) with a zig-zag incision pattern. Patients were assessed preoperatively and underwent postoperative comprehensive examinations at standard intervals of 1, 3, 6, 9, and 12 months, and 6 months thereafter. Postoperative uncorrected distance visual acuity and spectacle-corrected distance visual acuity and manifest and topographical (Mrx cyl and Topo cyl) astigmatism were compared with preoperative values. Results: Three hundred thirty-five eyes received FLEK with zig-zag configuration. Data are presented for the last recorded visit before any refractive procedure. Sutures were removed in 202 of 335 eyes at an average time to removal of 1.3 ± 1.1 years, and a mean follow-up period of 2.9 ± 2.1 years (range 0–10 years). After full suture removal, mean uncorrected distance visual acuity and spectacle-corrected distance visual acuity were logarithm of the minimum angle of resolution 0.84 (Snellen 20/138) ± 0.55 and 0.33 (Snellen 20/42) ± 0.33, respectively. Mean Mrx cyl and Topo cyl of these groups were 3.38 ± 2.22 and 4.77 ± 3.15, respectively. Of the total number of grafts, the rate of graft rejections was 14.0%, and the failure rate was 5.6%. Conclusions: The femtosecond laser–generated zig-zag–shaped incision results in lower manifestAbstract : Purpose: To report long-term visual and astigmatism outcomes in cases of zig-zag femtosecond laser–enabled penetrating keratoplasty (FLEK). Methods: Retrospective review. Three hundred thirty-five eyes of 287 patients underwent (FLEK) with a zig-zag incision pattern. Patients were assessed preoperatively and underwent postoperative comprehensive examinations at standard intervals of 1, 3, 6, 9, and 12 months, and 6 months thereafter. Postoperative uncorrected distance visual acuity and spectacle-corrected distance visual acuity and manifest and topographical (Mrx cyl and Topo cyl) astigmatism were compared with preoperative values. Results: Three hundred thirty-five eyes received FLEK with zig-zag configuration. Data are presented for the last recorded visit before any refractive procedure. Sutures were removed in 202 of 335 eyes at an average time to removal of 1.3 ± 1.1 years, and a mean follow-up period of 2.9 ± 2.1 years (range 0–10 years). After full suture removal, mean uncorrected distance visual acuity and spectacle-corrected distance visual acuity were logarithm of the minimum angle of resolution 0.84 (Snellen 20/138) ± 0.55 and 0.33 (Snellen 20/42) ± 0.33, respectively. Mean Mrx cyl and Topo cyl of these groups were 3.38 ± 2.22 and 4.77 ± 3.15, respectively. Of the total number of grafts, the rate of graft rejections was 14.0%, and the failure rate was 5.6%. Conclusions: The femtosecond laser–generated zig-zag–shaped incision results in lower manifest and topographical astigmatism than the reported average for conventional penetrating keratoplasty. Graft rejection and failure rates are similar to published data for conventional penetrating keratoplasty. … (more)
- Is Part Of:
- Cornea. Volume 38:Issue 1(2019)
- Journal:
- Cornea
- Issue:
- Volume 38:Issue 1(2019)
- Issue Display:
- Volume 38, Issue 1 (2019)
- Year:
- 2019
- Volume:
- 38
- Issue:
- 1
- Issue Sort Value:
- 2019-0038-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-01
- Subjects:
- femtosecond laser–enabled keratoplasty -- zig-zag trephination -- conventional penetrating keratoplasty
Cornea -- Periodicals
Cornea -- Periodicals
Cornée -- Périodiques
617.719 - Journal URLs:
- http://journals.lww.com/corneajrnl/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/ICO.0000000000001783 ↗
- Languages:
- English
- ISSNs:
- 0277-3740
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3470.927500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11295.xml