Visual and Semiquantitative Accuracy in Clinical Baseline 123I-Ioflupane SPECT/CT Imaging. (January 2019)
- Record Type:
- Journal Article
- Title:
- Visual and Semiquantitative Accuracy in Clinical Baseline 123I-Ioflupane SPECT/CT Imaging. (January 2019)
- Main Title:
- Visual and Semiquantitative Accuracy in Clinical Baseline 123I-Ioflupane SPECT/CT Imaging
- Authors:
- Werner, Rudolf A.
Marcus, Charles
Sheikhbahaei, Sara
Solnes, Lilja B.
Leal, Jeffrey P.
Du, Yong
Rowe, Steven P.
Higuchi, Takahiro
Buck, Andreas K.
Lapa, Constantin
Javadi, Mehrbod S. - Abstract:
- Abstract : Purpose: We aimed to (a) elucidate the concordance of visual assessment of an initial 123 I-ioflupane scan by a human interpreter with comparison to results using a fully automatic semiquantitative method and (b) to assess the accuracy compared to follow-up (f/u) diagnosis established by movement disorder specialists. Methods: An initial 123 I-ioflupane scan was performed in 382 patients with clinically uncertain Parkinsonian syndrome. An experienced reader performed a visual evaluation of all scans independently. The findings of the visual read were compared with semiquantitative evaluation. In addition, available f/u clinical diagnosis (serving as a reference standard) was compared with results of the human read and the software. Results: When comparing the semiquantitative method with the visual assessment, discordance could be found in 25 (6.5%) of 382 of the cases for the experienced reader (ĸ = 0.868). The human observer indicated region of interest misalignment as the main reason for discordance. With neurology f/u serving as reference, the results of the reader revealed a slightly higher accuracy rate (87.7%, ĸ = 0.75) compared to semiquantification (86.2%, ĸ = 0.719, P < 0.001, respectively). No significant difference in the diagnostic performance of the visual read versus software-based assessment was found. Conclusions: In comparison with a fully automatic semiquantitative method in 123 I-ioflupane interpretation, human assessment obtained an almostAbstract : Purpose: We aimed to (a) elucidate the concordance of visual assessment of an initial 123 I-ioflupane scan by a human interpreter with comparison to results using a fully automatic semiquantitative method and (b) to assess the accuracy compared to follow-up (f/u) diagnosis established by movement disorder specialists. Methods: An initial 123 I-ioflupane scan was performed in 382 patients with clinically uncertain Parkinsonian syndrome. An experienced reader performed a visual evaluation of all scans independently. The findings of the visual read were compared with semiquantitative evaluation. In addition, available f/u clinical diagnosis (serving as a reference standard) was compared with results of the human read and the software. Results: When comparing the semiquantitative method with the visual assessment, discordance could be found in 25 (6.5%) of 382 of the cases for the experienced reader (ĸ = 0.868). The human observer indicated region of interest misalignment as the main reason for discordance. With neurology f/u serving as reference, the results of the reader revealed a slightly higher accuracy rate (87.7%, ĸ = 0.75) compared to semiquantification (86.2%, ĸ = 0.719, P < 0.001, respectively). No significant difference in the diagnostic performance of the visual read versus software-based assessment was found. Conclusions: In comparison with a fully automatic semiquantitative method in 123 I-ioflupane interpretation, human assessment obtained an almost perfect agreement rate. However, compared to clinical established diagnosis serving as a reference, visual read seemed to be slightly more accurate as a solely software-based quantitative assessment. … (more)
- Is Part Of:
- Clinical nuclear medicine. Volume 44:Number 1(2019)
- Journal:
- Clinical nuclear medicine
- Issue:
- Volume 44:Number 1(2019)
- Issue Display:
- Volume 44, Issue 1 (2019)
- Year:
- 2019
- Volume:
- 44
- Issue:
- 1
- Issue Sort Value:
- 2019-0044-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-01
- Subjects:
- Parkinson disease -- parkinsonism -- DaTscan -- 123I-ioflupane -- SPECT -- SPECT/CT
Nuclear medicine -- Periodicals
Radioisotope scanning -- Periodicals
Nuclear Medicine -- Periodicals
616.07575 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=00003072-000000000-00000 ↗
http://journals.lww.com/nuclearmed/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/RLU.0000000000002333 ↗
- Languages:
- English
- ISSNs:
- 0363-9762
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.314000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11310.xml