Analysis of components of variance determining probability of setup errors in CBCT‐guided stereotactic radiotherapy of lung tumors. Issue 2 (2nd February 2017)
- Record Type:
- Journal Article
- Title:
- Analysis of components of variance determining probability of setup errors in CBCT‐guided stereotactic radiotherapy of lung tumors. Issue 2 (2nd February 2017)
- Main Title:
- Analysis of components of variance determining probability of setup errors in CBCT‐guided stereotactic radiotherapy of lung tumors
- Authors:
- Cuijpers, Johan P.
Dahele, Max
Jonker, Marianne
Kraan, Bianca
Senan, Suresh
Slotman, Ben
Verbakel, Wilko FAR - Abstract:
- Abstract : Purpose: Online tumor matching for SABR lung setup requires margins for inaccuracies due to intra‐fraction variability of breathing‐averaged tumor position (BATP) and CBCT image guidance. We studied intra‐fraction variability during SABR delivery using VMAT, corrected these for measurement inaccuracies, and quantified the CBCT image‐guidance uncertainties. Materials and methods: For 193 fractions in 38 patients positioned without immobilization devices, CBCT scans were acquired before and after 2 arcs of a RapidArc treatment. A hidden marker test was performed to determine the accuracy of the CBCT system and an inter‐observer test was performed to measure registration accuracy. Intra‐fraction variability was calculated after correction for these components of variance, and the prediction interval for setup inaccuracies was determined. Results: Correction for measurement inaccuracies reduced the intra‐fraction variability of the BATP from 1.9 to 1.6 mm in AP, from 1.7 to 1.4 mm in SI and from 1.5 to 1.1 mm in LR direction (1 SD). Intra‐fraction variability in bony anatomy after correction was ≤ 1 mm (1 SD). The 95% prediction interval to account for CBCT image‐guidance uncertainties and intra‐fraction variability was determined, and was found to be within our institutional PTV margins of 5 mm. Conclusions: Our findings show that it is essential to account for measurement and system inaccuracies when obtaining data for validating PTV margins from online CBCT imageAbstract : Purpose: Online tumor matching for SABR lung setup requires margins for inaccuracies due to intra‐fraction variability of breathing‐averaged tumor position (BATP) and CBCT image guidance. We studied intra‐fraction variability during SABR delivery using VMAT, corrected these for measurement inaccuracies, and quantified the CBCT image‐guidance uncertainties. Materials and methods: For 193 fractions in 38 patients positioned without immobilization devices, CBCT scans were acquired before and after 2 arcs of a RapidArc treatment. A hidden marker test was performed to determine the accuracy of the CBCT system and an inter‐observer test was performed to measure registration accuracy. Intra‐fraction variability was calculated after correction for these components of variance, and the prediction interval for setup inaccuracies was determined. Results: Correction for measurement inaccuracies reduced the intra‐fraction variability of the BATP from 1.9 to 1.6 mm in AP, from 1.7 to 1.4 mm in SI and from 1.5 to 1.1 mm in LR direction (1 SD). Intra‐fraction variability in bony anatomy after correction was ≤ 1 mm (1 SD). The 95% prediction interval to account for CBCT image‐guidance uncertainties and intra‐fraction variability was determined, and was found to be within our institutional PTV margins of 5 mm. Conclusions: Our findings show that it is essential to account for measurement and system inaccuracies when obtaining data for validating PTV margins from online CBCT image guidance. … (more)
- Is Part Of:
- Medical physics. Volume 44:Issue 2(2017)
- Journal:
- Medical physics
- Issue:
- Volume 44:Issue 2(2017)
- Issue Display:
- Volume 44, Issue 2 (2017)
- Year:
- 2017
- Volume:
- 44
- Issue:
- 2
- Issue Sort Value:
- 2017-0044-0002-0000
- Page Start:
- 382
- Page End:
- 388
- Publication Date:
- 2017-02-02
- Subjects:
- intra‐fraction motion -- lung cancer -- SABR -- SBRT -- setup errors
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.12074 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11308.xml