Using rotational thromboelastometry clot firmness at 5 minutes (ROTEM® EXTEM A5) to predict massive transfusion and in‐hospital mortality in trauma: a retrospective analysis of 1146 patients. (16th April 2018)
- Record Type:
- Journal Article
- Title:
- Using rotational thromboelastometry clot firmness at 5 minutes (ROTEM® EXTEM A5) to predict massive transfusion and in‐hospital mortality in trauma: a retrospective analysis of 1146 patients. (16th April 2018)
- Main Title:
- Using rotational thromboelastometry clot firmness at 5 minutes (ROTEM® EXTEM A5) to predict massive transfusion and in‐hospital mortality in trauma: a retrospective analysis of 1146 patients
- Authors:
- Kelly, J. M.
Rizoli, S.
Veigas, P.
Hollands, S.
Min, A. - Abstract:
- Summary: Viscoelastic assays such as TEG ® and ROTEM ® are increasingly used to guide transfusion of blood products. The EXTEM assay maximum clot firmness (MCF) is a ROTEM measure available after 25–29 min used to guide early decisions. EXTEM A10, the clot firmness at 10 min, is an accepted early surrogate, but investigators differ on whether A5, the clot firmness at 5 min, is acceptable. We re‐examined this in a retrospective observational analysis of 1146 trauma patients in one centre who had ROTEM data recorded. A5 and A10 both correlated well with maximum clot firmness, with Pearson coefficients of r = 0.92 and r = 0.96, respectively. The correlations of A5, A10 and maximum clot firmness with requirement for massive transfusion were all similarly high, with c‐stats of 0.87, 0.89 and 0.90, respectively. The correlations with mortality were also similar but weaker, with c‐stats of 0.67, 0.69 and 0.69, respectively. Using a previously validated cut‐off of A5 < 35 mm to predict massive transfusion gave a sensitivity of 95%, specificity 83%, positive predictive value 9.3% and negative predictive value 100%. Using a value of A5 < 29 mm, for a pragmatic positive predictive value of 20%, gave a sensitivity of 67%, specificity 95% and negative predictive value 99%. Whether aiming for a high sensitivity or a strong predictive value, A5 was non‐inferior to A10 and actually missed fewer cases needing massive transfusion. A5 has similar utility to both A10 and maximum clot firmnessSummary: Viscoelastic assays such as TEG ® and ROTEM ® are increasingly used to guide transfusion of blood products. The EXTEM assay maximum clot firmness (MCF) is a ROTEM measure available after 25–29 min used to guide early decisions. EXTEM A10, the clot firmness at 10 min, is an accepted early surrogate, but investigators differ on whether A5, the clot firmness at 5 min, is acceptable. We re‐examined this in a retrospective observational analysis of 1146 trauma patients in one centre who had ROTEM data recorded. A5 and A10 both correlated well with maximum clot firmness, with Pearson coefficients of r = 0.92 and r = 0.96, respectively. The correlations of A5, A10 and maximum clot firmness with requirement for massive transfusion were all similarly high, with c‐stats of 0.87, 0.89 and 0.90, respectively. The correlations with mortality were also similar but weaker, with c‐stats of 0.67, 0.69 and 0.69, respectively. Using a previously validated cut‐off of A5 < 35 mm to predict massive transfusion gave a sensitivity of 95%, specificity 83%, positive predictive value 9.3% and negative predictive value 100%. Using a value of A5 < 29 mm, for a pragmatic positive predictive value of 20%, gave a sensitivity of 67%, specificity 95% and negative predictive value 99%. Whether aiming for a high sensitivity or a strong predictive value, A5 was non‐inferior to A10 and actually missed fewer cases needing massive transfusion. A5 has similar utility to both A10 and maximum clot firmness as an early measure of clot firmness, and a low A5 value is strongly predictive of the need for massive transfusion. … (more)
- Is Part Of:
- Anaesthesia. Volume 73:Number 9(2018)
- Journal:
- Anaesthesia
- Issue:
- Volume 73:Number 9(2018)
- Issue Display:
- Volume 73, Issue 9 (2018)
- Year:
- 2018
- Volume:
- 73
- Issue:
- 9
- Issue Sort Value:
- 2018-0073-0009-0000
- Page Start:
- 1103
- Page End:
- 1109
- Publication Date:
- 2018-04-16
- Subjects:
- bleeding -- massive transfusion -- ROTEM -- trauma, coagulation
Anesthesia -- Periodicals
617.96 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1365-2044 ↗
http://onlinelibrary.wiley.com/ ↗
http://www.aagbi.org/publications ↗ - DOI:
- 10.1111/anae.14297 ↗
- Languages:
- English
- ISSNs:
- 0003-2409
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0859.900000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11307.xml