An empirical study on environmental impact of natural draft cooling tower with flue gas injection. Issue 1 (1st January 2018)
- Record Type:
- Journal Article
- Title:
- An empirical study on environmental impact of natural draft cooling tower with flue gas injection. Issue 1 (1st January 2018)
- Main Title:
- An empirical study on environmental impact of natural draft cooling tower with flue gas injection
- Authors:
- Su, Shenshen
Zhang, Renfeng
Ma, JiJun
Xie, Yongping
Sun, Xijin
Han, Jianhua - Abstract:
- Abstract: In order to understand the influences of natural draft cooling tower (NDCT) with flue gas injection on pollutant concentrations of the theoretical plume downwash area, an automatic air quality monitoring station was set in the theoretical plume downwash area of NDCT in Qinling power plant to get hourly SO2 and NO2 concentrations over a year. The results show that: 100% 1h average concentrations of SO2 and 99.64% NO2 observations satisfied the requirements of Chinese ambient air quality standard. High pollutant concentrations caused by plume downwash of NDCT with flue gas injection are not observed during the monitoring period, and there are no significant differences ( P > 0.05) between pollutant concentrations in the theoretical plume downwash area under the prevailing westerly wind conditions (37.2 ± 24.8 μg/m 3 ) and easterly wind conditions (36.9 ± 22.3 μg/m 3 ), while the concentrations under conditions of west wind speed > 5m/s are significantly lower ( P < 0.01) than those under conditions of west wind speed < 1.2m/s. The observations of this study indicate that ground pollutants at high concentration owing to plume downwash would not occur in the theoretical plume downwash area of NDCT with flue gas injection.
- Is Part Of:
- Journal of International Council on Electrical Engineering. Volume 8:Issue 1(2018)
- Journal:
- Journal of International Council on Electrical Engineering
- Issue:
- Volume 8:Issue 1(2018)
- Issue Display:
- Volume 8, Issue 1 (2018)
- Year:
- 2018
- Volume:
- 8
- Issue:
- 1
- Issue Sort Value:
- 2018-0008-0001-0000
- Page Start:
- 44
- Page End:
- 50
- Publication Date:
- 2018-01-01
- Subjects:
- Natural draft cooling tower with flue gas injection -- automatic air quality monitoring station -- plume downwash -- statistical test -- environmental protection zone
Electrical engineering -- Periodicals
Electrical engineering
Periodicals
621.3 - Journal URLs:
- http://www.tandfonline.com/loi/tjee20 ↗
http://www.tandfonline.com/ ↗ - DOI:
- 10.1080/22348972.2018.1464110 ↗
- Languages:
- English
- ISSNs:
- 2233-5951
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11275.xml