Resonant Synchrotron X-ray Diffraction determines markers for iron-rich atmospheric particulate matter in urban region. (December 2018)
- Record Type:
- Journal Article
- Title:
- Resonant Synchrotron X-ray Diffraction determines markers for iron-rich atmospheric particulate matter in urban region. (December 2018)
- Main Title:
- Resonant Synchrotron X-ray Diffraction determines markers for iron-rich atmospheric particulate matter in urban region
- Authors:
- Galvão, Elson Silva
Santos, Jane Meri
Lima, Ana Teresa
Reis, Neyval Costa
Stuetz, Richard Michael
Orlando, Marcos Tadeu D'Azeredo - Abstract:
- Abstract: Particulate matter driven health problems are strongly associated with its chemical composition. Despite the benefits of using source apportionment models for air quality management, limitations such as collinearity effects, restrict their application or compromise the accurate separation of sources, particularly for particulate matter with similar chemical profiles. Receptors models also depend on the operator expertise to appropriately classified sources, a subjective process that can lead to biased results. For highly correlated sources, the identification of specific markers is still the best way to achieve proper source apportionment. In this study, Resonant Synchrotron X-ray Diffraction has been applied to the analysis of atmospheric particles to determine markers for industrial and vehicular sources in the Region of Greater Vitória, Brazil. Total suspended particulate matter, PM10, and PM2.5 samples were analyzed by Resonant Synchrotron X-ray Diffraction showing high levels of iron-based crystalline phases. In comparison to the use of chemical elemental species, the identification of the crystalline phases provided an enhanced approach to classify specific iron-based source markers. For this study, α-Fe2 O3 was identified with iron-based sources such as iron ore, pelletizing, and sintering; metallic Fe was inferred with blast furnaces and steelmaking; FeS2 was correlated with coal deposits; and K2 Fe2 O4 was associated to sintering emissions. ElementalAbstract: Particulate matter driven health problems are strongly associated with its chemical composition. Despite the benefits of using source apportionment models for air quality management, limitations such as collinearity effects, restrict their application or compromise the accurate separation of sources, particularly for particulate matter with similar chemical profiles. Receptors models also depend on the operator expertise to appropriately classified sources, a subjective process that can lead to biased results. For highly correlated sources, the identification of specific markers is still the best way to achieve proper source apportionment. In this study, Resonant Synchrotron X-ray Diffraction has been applied to the analysis of atmospheric particles to determine markers for industrial and vehicular sources in the Region of Greater Vitória, Brazil. Total suspended particulate matter, PM10, and PM2.5 samples were analyzed by Resonant Synchrotron X-ray Diffraction showing high levels of iron-based crystalline phases. In comparison to the use of chemical elemental species, the identification of the crystalline phases provided an enhanced approach to classify specific iron-based source markers. For this study, α-Fe2 O3 was identified with iron-based sources such as iron ore, pelletizing, and sintering; metallic Fe was inferred with blast furnaces and steelmaking; FeS2 was correlated with coal deposits; and K2 Fe2 O4 was associated to sintering emissions. Elemental carbon with different X-ray diffraction patterns enabled the differentiation of industrial and vehicular sources. The attribution of crystal rather than elemental composition in the identification of sources improves the accuracy of source apportionment studies. Graphical abstract: Highlights: Particulate matter (PM) has been the subject of intricate air quality studies. For high correlated sources, specific markers can improve the source apportionment. Resonant Synchrotron-XRD determines markers for industrial and vehicular sources. The Identification of specific crystal phases can act as marker of specific sources. RSr-XRD proves to be an improved way to contour source collinearity problems. … (more)
- Is Part Of:
- Chemosphere. Volume 212(2018)
- Journal:
- Chemosphere
- Issue:
- Volume 212(2018)
- Issue Display:
- Volume 212, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 212
- Issue:
- 2018
- Issue Sort Value:
- 2018-0212-2018-0000
- Page Start:
- 418
- Page End:
- 428
- Publication Date:
- 2018-12
- Subjects:
- Particulate matter (PM) -- Resonant Synchrotron X-ray Diffraction (RSr-XRD) -- Chemical composition -- Crystalline phases -- Source apportionment -- Source markers
Pollution -- Periodicals
Pollution -- Physiological effect -- Periodicals
Environmental sciences -- Periodicals
Atmospheric chemistry -- Periodicals
551.511 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00456535/ ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.chemosphere.2018.08.111 ↗
- Languages:
- English
- ISSNs:
- 0045-6535
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3172.280000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11278.xml