Mortality After Paclitaxel-Coated Device Use in Dialysis Access: A Systematic Review and Meta-Analysis. (October 2019)
- Record Type:
- Journal Article
- Title:
- Mortality After Paclitaxel-Coated Device Use in Dialysis Access: A Systematic Review and Meta-Analysis. (October 2019)
- Main Title:
- Mortality After Paclitaxel-Coated Device Use in Dialysis Access: A Systematic Review and Meta-Analysis
- Authors:
- Dinh, Krystal
Limmer, Alexandra M.
Paravastu, Sharath C. V.
Thomas, Shannon D.
Bennett, Michael H.
Holden, Andrew
Varcoe, Ramon L. - Abstract:
- Purpose: To report the risk of all-cause mortality in patients who underwent dialysis access treatment using paclitaxel-coated devices compared with percutaneous transluminal angioplasty (PTA) with an uncoated balloon.Materials and Methods: A systematic review and meta-analysis of randomized controlled trials were performed to investigate the mortality outcomes associated with paclitaxel-coated devices in the treatment of patients with a failing dialysis access (last search date February 28, 2019). The primary endpoint was all-cause mortality. This analysis included 8 studies comparing paclitaxel-coated balloon (PCB) angioplasty (n=327) and PTA (n=331) in the treatment of failing dialysis access. None investigated paclitaxel-coated stents. Mortality data were pooled using a random effects model. Statistical heterogeneity was evaluated with a chi-square test and the I 2 statistic. Summary statistics are expressed as relative risk ratios (RR) with a 95% confidence interval (CI).Results: At the pooled mean follow-up of 13.5 months (median 12, range 6–24) all-cause mortality was similar in the PCB group (13.8%) compared with PTA (11.2%; RR 1.26, 95% CI 0.85 to 1.89, p=0.25; I 2 =0%). Subgroup analysis, stratified according to length of follow-up, confirmed that there were no statistically significant differences in mortality at short- and midterm follow-up [6-month (8 studies): 5.2% vs 4.8%, RR 1.24, 95% CI 0.62 to 2.47, p=0.55; 12-month (6 studies): 6.3% vs 6.0%, RR 1.06, 95%Purpose: To report the risk of all-cause mortality in patients who underwent dialysis access treatment using paclitaxel-coated devices compared with percutaneous transluminal angioplasty (PTA) with an uncoated balloon.Materials and Methods: A systematic review and meta-analysis of randomized controlled trials were performed to investigate the mortality outcomes associated with paclitaxel-coated devices in the treatment of patients with a failing dialysis access (last search date February 28, 2019). The primary endpoint was all-cause mortality. This analysis included 8 studies comparing paclitaxel-coated balloon (PCB) angioplasty (n=327) and PTA (n=331) in the treatment of failing dialysis access. None investigated paclitaxel-coated stents. Mortality data were pooled using a random effects model. Statistical heterogeneity was evaluated with a chi-square test and the I 2 statistic. Summary statistics are expressed as relative risk ratios (RR) with a 95% confidence interval (CI).Results: At the pooled mean follow-up of 13.5 months (median 12, range 6–24) all-cause mortality was similar in the PCB group (13.8%) compared with PTA (11.2%; RR 1.26, 95% CI 0.85 to 1.89, p=0.25; I 2 =0%). Subgroup analysis, stratified according to length of follow-up, confirmed that there were no statistically significant differences in mortality at short- and midterm follow-up [6-month (8 studies): 5.2% vs 4.8%, RR 1.24, 95% CI 0.62 to 2.47, p=0.55; 12-month (6 studies): 6.3% vs 6.0%, RR 1.06, 95% CI 0.43 to 2.63, p=0.90; and 24-month (3 studies): 19.0% vs 13.5%, RR 1.38, 95% CI 0.90 to 2.12, p=0.14).Conclusion: The analysis found no difference in short- to midterm mortality among patients treated with a drug-coated balloon compared with PTA. With proven benefit and no evidence of harm, the authors recommend ongoing use of PCB for the failing dialysis access. … (more)
- Is Part Of:
- Journal of endovascular therapy. Volume 26:Number 5(2019:Oct.)
- Journal:
- Journal of endovascular therapy
- Issue:
- Volume 26:Number 5(2019:Oct.)
- Issue Display:
- Volume 26, Issue 5 (2019)
- Year:
- 2019
- Volume:
- 26
- Issue:
- 5
- Issue Sort Value:
- 2019-0026-0005-0000
- Page Start:
- 600
- Page End:
- 612
- Publication Date:
- 2019-10
- Subjects:
- arteriovenous fistula -- arteriovenous graft -- balloon angioplasty -- drug-coated balloon -- drug-eluting stents -- failing dialysis access -- hemodialysis -- mortality -- paclitaxel -- stenosis
Blood-vessels -- Endoscopic surgery -- Periodicals
Angioscopy -- Periodicals
Intravenous catheterization -- Periodicals
Peripheral vascular diseases -- Treatment -- Periodicals
Vascular Surgical Procedures -- Periodicals
Angioscopy -- Periodicals
Catheterization, Peripheral -- Periodicals
Peripheral Vascular Diseases -- therapy -- Periodicals
Angioscopie
Maladies vasculaires périphériques
617.413 - Journal URLs:
- http://jet.sagepub.com/ ↗
http://www.jevt.org ↗
http://www.uk.sagepub.com ↗ - DOI:
- 10.1177/1526602819872154 ↗
- Languages:
- English
- ISSNs:
- 1526-6028
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11273.xml