Recording characteristics of electrical impedance myography needle electrodes. (21st August 2017)
- Record Type:
- Journal Article
- Title:
- Recording characteristics of electrical impedance myography needle electrodes. (21st August 2017)
- Main Title:
- Recording characteristics of electrical impedance myography needle electrodes
- Authors:
- Kwon, H
Rutkove, S B
Sanchez, B - Abstract:
- Abstract: Objective : Neurologists and physiatrists need improved tools for the evaluation of skeletal muscle condition. Here we evaluate needle electrical impedance myography (EIM), a new minimally invasive approach to determine muscle status that could ultimately become a bedside tool for the assessment of neuromuscular disorders. Approach : We design and study the recording characteristics of tetrapolar EIM needle electrodes combining theory and finite-element model simulations. We then use these results to build and pilot in vivo an EIM needle electrode in the rat gastrocnemius muscle ( n = 2 ). The dielectric properties of muscle are reported (mean ± standard deviation). Results : The numerical simulations show that the contribution of subcutaneous fat and muscle tissues to needle EIM data is <3% and >97%, respectively, and the sensed volume is 0.70 cm 3 . Apparent resistivity 277 ± 30 Ω cm and relative permittivity ( 1 ± 0.4 ) × 10 5 (dimensionless) measured at 10 kHz are in good agreement with in vivo dielectric properties reported in the literature. Significance : The results presented show the feasibility of measuring muscle impedivity in vivo using a needle electrode from 10 kHz to 1 MHz. The development of needle EIM technology can open up a new field of study in electrodiagnostic medicine, with potential applications to both disease diagnosis and biomarker assessment of therapy.
- Is Part Of:
- Physiological measurement. Volume 38:Number 9(2017:Sep.)
- Journal:
- Physiological measurement
- Issue:
- Volume 38:Number 9(2017:Sep.)
- Issue Display:
- Volume 38, Issue 9 (2017)
- Year:
- 2017
- Volume:
- 38
- Issue:
- 9
- Issue Sort Value:
- 2017-0038-0009-0000
- Page Start:
- 1748
- Page End:
- 1765
- Publication Date:
- 2017-08-21
- Subjects:
- electrical impedance myography -- needle electrodes -- four-electrode technique -- in vivo rat muscle
Physiology -- Measurement -- Periodicals
Patient monitoring -- Periodicals
612 - Journal URLs:
- http://ioppublishing.org/ ↗
http://iopscience.iop.org/0967-3334 ↗ - DOI:
- 10.1088/1361-6579/aa80ac ↗
- Languages:
- English
- ISSNs:
- 0967-3334
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11270.xml